Data Rate: 10 Mbits / sec

Partitioning: Enforced after 32 consecutive collisions.

Reconnect: Occurs after 512 bits of error-free transmission.

Network Standards

Ethernet V 1.0/V2.0 IEEE 802.3: 10BASE-T, 10BASE5, 10BASE2, 10BASE-FL & FOIRL, and DTE

(The Magnum 200X Two-Port Repeaters are physical layer standard Ethernet products, and operate independently of all software.)

Maximum Ethernet Segment Lengths

 

DTE (AUI Drop Cable)

- 50 m (164 ft)

10BASE-T (twisted pair)

- 100 m (328 ft)

Shielded twisted pair

- 150m (492 ft)

10BASE2 ThinNet (BNC)

- 185 m (607 ft)

10BASE5 ThickNet

- 500 m (1,640 ft)

FOIRL multi-mode Fiber optic

- 1 km (3,281 ft)

10BASE-FL multi-mode Fiber optic

- 2 km (6,562 ft)

Single-mode Fiber optic

- 10 km (32,810 ft)

Connectors

200X: Two Magnum RPM ports on the front, AC power in rear.

RPMs available with standard 200X models:

RPM -TP: Shielded female RJ-45 with up -link switch

(Note: Shielded 10BASE-T connectors accept either unshielded or

shielded wiring plugs for standard twisted pair media wiring.)

RPM -BNC: ThinNet (BNC) connector with internal termination switch

RPM -AUI: D-Sub 15-Pin Female with slide lock

RPM -FST: Multi-mode fiber 10BASE-FL ST (dual "twist lock") connector