GarrettCom Magnum 700X manual Bpm-Aui, Bpm-Fst, Magnum BPM-FST

Models: Magnum 700X

1 39
Download 39 pages 34.08 Kb
Page 20
Image 20
2
Magnum BPM-AUI
1
2 FWD-I LED
1 FWD-X LED
Standard 15-pin
female AUI
with slide-lock

Magnum 700X Mini-Concentrators

Installation and User Guide (05/98)

 

 

the RPM-BNC section, 2.3.1. The BPM-BNC module includes an FWD-I LED and an FWD-X LED, which are visible from the front. The FWD-I LED blinks GREEN to indicate that packets are being forwarded INTO the local Magnum hub or stack.. The FWD-X LED blinks GREEN to indicate that packets are being forwarded OUT of the local Magnum hub or stack.

2.4.2BPM-AUI

This local-bridge module is equipped with a 15 pin female AUI connector and a slide- lock. It is self-learning and filters and forwards packets at full Ethernet wire speed. It is used to provide segment isolation from a 10BASE5

(ThickNet) backbone or any AUI segments. A

transceiver is required when connecting to a ThickNet segment and the BPM-AUI supports this convention.

The BPM-AUI card is equipped with one FWD-I LED and one FWD-X LED, which are identical to those of the BPM-BNC

(see Section 2.4.1).

The RPM-AUI connector supports standard IEEE signals, which are summarized in Table 2.3.2 of Section 2.3.2.

2.4.3BPM-FST

The Magnum BPM-FST is a multi- mode fiber optic local-bridge module equipped with a dual ST-type connector. It is self-learning and filters and forwards packets at full Ethernet wire speed. When used for 10BASE-FL segments, this module supports fiber optic

10BASE-FL, FOIRL

ST Connectors

2

1

3

1FWD-X LED

2 FWD-I LED

3 LINK LED

transmission distances up to 2000m. For FOIRL,

Magnum BPM-FST

it supports fiber segments of up to 1000m in length. The BPM-FST includes full transceiver functionality and does not require an external transceiver device. The BPM-FST has three status LEDs. FWD-I and FWD-X are identical to those of the BPM-BNC (Section 2.4.1). In addition, this module has a GREEN LINK LED, that is always on when the link is operational.

GARRETT

15

Page 20
Image 20
GarrettCom Magnum 700X manual Bpm-Aui, Bpm-Fst, Magnum BPM-FST