GarrettCom Magnum 700X Technical Specifications, Connectors, Packaging, LED Indicators on Chassis

Models: Magnum 700X

1 39
Download 39 pages 34.08 Kb
Page 7
Image 7

Magnum 700X Mini-Concentrators

Installation and User Guide (05/98)

(1.1 Technical Specifications, continued) Connectors

Seven Magnum PM ports on the front. BPMs are available with BNC, AUI, FST, and STP connectors. The following are available as RPM configurations.

RJ-45:

Shielded, 8-Pin Female (Note: Shielded 10BASE-T

 

connectors accept either unshielded or shielded wiring

 

plugs for standard twisted pair media wiring.)

Fiber Optic:

ST (Twist-Lock Connector, for single or multi-mode)

Fiber Optic:

SMA (screw-on Connector, for multi-mode, by special order only)

ThinNet:

BNC

AUI:

D-Sub 15-Pin Female (with slide lock)

DTE:

D-Sub 15-Pin Male (with lock posts)

Note: Port Modules are also used with the Magnum 3000X, and as the Bonus Port modules for Magnum Stackable and Workgroup Hubs. All Port Modules should be installed at the factory or by trained technicians.

Packaging

Enclosure: High strength sheet metal.

Suitable for wiring closet shelf, wall or desktop mounting.

Port Module Slots: 7

Dimensions: 6.0 in x 10.0 in. x 3.5 in. (15.25 cm x 25.4 cm x 8.89 cm)

Weight: 2.5 lb. (1.1 Kg)

Port Slot Cut-out: 2.2 in. x .75 in. (5.6 cm x 1.9 cm)

Cooling method: Convection

LED Indicators on Chassis

Four chassis LEDs monitor the general status of the unit including network traffic.

PWR - Power, Green LED, steady ON indicates there is AC power. RX - Receive, Green LED, blinks to indicate network activity, data

being received from any of the PMs.

JAB - Jabber, Amber LED, illuminates when jabber condition (illegal packet size) is detected on any port; affected port is partitioned temporarily until jabber stops.

COL - Collision, Yellow LED, flashes when a collision is detected on any of the PMs.

For the LEDs on each PM, see "Product Description" of the PMs.

Agency Approvals

 

UL Listed (UL 1950), cUL, CE

 

Emissions: meets FCC Part 15, Class A

 

Warranty

 

Three years, return to factory

Made in USA