Magnum 700X Mini-Concentrators

Installation and User Guide (05/98)

 

 

Magnum 700X

Mini-Concentrator

eu

GARRETT

Network Connection to

External Network via BPM

Local User Ports with Heavy Local Traffic,

Connected to Magnum RPMs

Figure 3.12.2e: Local Isolation with Bridge Port Module

3.Bridge Transparency: The BPMs are transparent to both the user and the application software.

4.LINK and Traffic Status: The Magnum BPM-TP and BPM-FST indicate link integrity with an LED. This LINK LED is normally lit. An unlit LINK LED indicates a broken cable or loss of power at some point in the segment. All BPMs have FWD-I and FWD-X status LEDs. The FWD-I LED flashes when packets are forwarded into the local segment. The FWD-X LED flashes when packets are forwarded out of the local segment.

5.Self-test Diagnostics: A BPM requires about 15 seconds upon power-up before bridging services are available. During this time, the BPM performs an internal self- test.

4.3Powering the Magnum 700X Mini-Concentrator

The Magnum 700X incorporates an internal universal power supply, and has a female

IEC connector for the AC power cord at the right-rear. A six foot 115 vac power cord is supplied with each unit. (Except units being shipped from the GCI factory outside the United States and Canada will not include a 115 vac power cord.)

The Magnum 700X supports installation environments where the AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz, and will consume no more than a maximum of 40 watts. The power connector is located on the back of the unit. In order to

GARRETT

29

Page 34
Image 34
GarrettCom manual 12.2e Local Isolation with Bridge Port Module, Powering the Magnum 700X Mini-Concentrator