Chapter 6: Troubleshooting

Open your server and make sure that the cables are connected correctly to the diskette drive and the system board. The red-striped edge of the data ribbon cable indicates Pin 1 and corresponds with Pin 1 on the diskette drive (typically on the side farthest from the power supply connection). If necessary, reverse one end of the cable so the red-striped edge of the data ribbon cable faces Pin 1 on the diskette drive. Make sure that the pins are not bent or misaligned. For more information, see “Installing a CD, DVD, or diskette drive” on page 30.

Expansion cards

Your server does not recognize an expansion card

Restart your server.

Make sure that you have installed the necessary software or driver. For more information, see the card’s documentation.

Reseat the card. For more information, see “Installing PCI expansion cards” on page 40.

Install the card in a different slot.

Hard drive

The hard drive cannot be accessed, or you receive a “General failure reading drive C” error message

If a diskette is in the diskette drive, eject it and press the reset button to restart your server.

Press the reset button to restart your server.

Use GWScan to test the hard drive. For more information, see “You need to troubleshoot an IDE hard drive” on page 76.

Open your server and make sure that the cables are connected correctly to the hard drive and the system board. For more information, see “Installing a hard drive” on page 35.

If your server has been subjected to static electricity or physical shock, you may need to reinstall the operating system.

74

www.gateway.com