CHAPTER 2: Getting Started

Introduction

Caution

When connecting the enclosure, use only the power cords supplied or cords which match the specification quoted in “Specifications” on page 29.

This chapter explains how to install your enclosure into an industry-standard, 19-inch rack cabinet and configure the enclosure sub-system.

Planning your installation

Caution

Blank modules or dummy carrier modules MUST be installed in ALL unused bays or

 

the enclosure may overheat.

 

 

Before you begin installation, you should become familiar with the configuration requirements of

 

your enclosure, detailed in the following table. The correct positions of each of the optional plug-in

 

modules are shown in the illustration. See “Ethernet connection” on page 24 and “Enclosure cabling

 

- multiple enclosures” on page 25 for details of controller module configurations.

 

 

 

Module

Location

 

 

 

Drive bays

All drive bays must have a drive carrier module or dummy drive carrier module installed. No bays should

 

be left empty.

 

 

 

Power supply (PSU)

Two power supply modules must be installed. Full power redundancy is provided while a faulty module

modules

is replaced. Install the power supply modules in the left rear bays, as shown in the following illustration.

 

 

 

Cooling module

Install the cooling module in the rear bay, as shown in the following illustration.

 

 

 

Controller module

Two RAID controller modules (or one controller module and one blank module) can be installed,

 

depending on the configuration you require. The modules are installed horizontally (one above the

 

other) in the right rear bay.

 

 

 

Disk I/O module

Two Disk I/O modules (or one Disk I/O module and one blank module) can be installed, depending on

 

the configuration you require. The modules are installed horizontally (one above the other) in the right

 

rear bay.

 

 

 

0

1

0

1

PSU 1

PSU 2

Cooling Module

RAID Controller 0

RAID Controller 1

Enclosure module

16