CHAPTER 4: Troubleshooting
Thermal alarm
Symptom | Cause | Action | |||
|
|
|
|
|
|
■ | Ops panel SYSTEM FAULT LED | ■ | If the internal temperature | ■ | Make sure that the local ambient environment |
| is orange. |
| measured in the airflow |
| temperature is below the upper 104°F (40°C) |
■ | An orange LED on one or |
| through the enclosure |
| specification. |
| more power supply module. |
| exceeds a | ■ | Check the installation for any airflow restrictions at |
■ | An audible alarm is sounding. |
| thermal alarm sounds. |
| either the front or rear of the enclosure. A minimum gap |
■ | Air temperature in the exiting | ■ | Cooling module failure. |
| of .98 inch (25 mm) at the front and 1.97 inches (50 mm) |
| power supply module is |
|
|
| at the rear is recommended. |
| above 131°F (55°C). |
|
| ■ | Check for restrictions caused by dust |
|
|
|
|
| as appropriate. |
|
|
|
| ■ | Check for excessive |
|
|
|
|
| rear to the front. Installing in a fully enclosed rack |
|
|
|
|
| installation is not recommended. |
|
|
|
| ■ | If possible, shutdown the enclosure and investigate the |
|
|
|
|
| problem before continuing. |
|
|
|
| ■ | Replace the cooling module. |
|
|
|
|
|
|
Thermal warnings
Symptom | Cause | Action | ||
|
|
|
|
|
■ | All orange LEDs on the Ops | The temperature is higher than the | ■ | Power off immediately. |
| panel and on all drive bays are | thermal alarm threshold (this should | ■ | Check for airflow restrictions. |
| flashing. | already have been activated). | ■ | Check for power supply module faults. |
■ | The audible alarm sounds | OR - All fans have failed. | ■ | Check for excessive local temperatures. |
| almost continuously and | OR - Only 1 fan is operating and the |
|
|
| cannot be muted. | internal temperature is 104°F (40°C) or |
|
|
|
| above. |
|
|
|
|
|
|
|
Make sure that you have obtained a replacement module of the same type before removing any faulty module.
Caution
If your Gateway
•Replace a faulty drive with a drive of the same type and equal or greater capacity.
•All drive bays must have a drive carrier or dummy carrier module installed in order to maintain a balanced airflow.
•All of the supplied