4.Press Option #. Panel announces, Option 1, press again for next option or done to select.
5.Press 81. Panel announces, Option 81, press again for next option or done to delete.
6.Press DONE. Panel announces, Option 81 deleted.
Option 82: Cooling Set PointNote
RF Thermostat must be in Cool Mode or Auto Mode for the option to work properly.
When this option is on you can set a temperature that will automatically turn the air conditioner on if the temperature rises above the set temperature. The commands are set through the control panel, to the RF Electronic Thermostat, when the system is armed to Doors & Windows and Motion Sensors.
Add allows you to set the temperature from 51°F - 91°F.
1.Open panel cover. Panel announces, Use numbered keys to enter ID.
2.Enter Master Code using the numbered keys. Panel announces, Please select from Start Menu.
3.Press Add from the Start menu. Panel announces, Select from main menu.
4.Press Option #. Panel announces, Option 1, press again for next option or done to select.
5.Press 82. Panel announces, Option 82, press again for next option or use numbered keys to enter option.
6.Enter the temperature (51 - 91) with the numbered keys.
7.Panel announces the temperature that has been selected.
Delete deletes the Cooling Set Point feature.
1.Open panel cover. Panel announces, Use numbered keys to enter ID.
2.Enter Master Code using the numbered keys. Panel announces, Please select from Start Menu.
3.Press Delete from the Start menu. Panel announces, Select from main menu.
4.Press Option #. Panel announces, Option 1, press again for next option or done to select.
5.Press 82. Panel announces, Option 82, press again for next option or done to delete.
6.Press DONE. Panel announces, Option 82 deleted.
Trouble Beeps
Your security system is able to automatically test itself for:
•Power failures
•Low batteries
•
•Communication troubles with the Central Monitoring Station
When your security system detects one of the problems above, six rapid beeps sound every minute, until the trouble condition is corrected.
Silencing Trouble BeepsTo stop the trouble beeps, press the SYSTEM STATUS button or arm/disarm the system while the trouble condition exists. Trouble beeps will begin 4 hours later, unless the trouble condition is corrected.
AC Power FailureThis condition occurs if your security system has been accidentally unplugged or if there has been an AC power outage. The backup battery will take over. If AC power is not restored within 15 seconds, the panel will go dark and alert you with trouble beeps. If you press any button, the display will light and pressing SYSTEM STATUS will confirm the AC power failure. If AC power is not restored within a programmed period of time