The panel cover was opened while the system was armed. The system will call the central monitoring station to report a tamper alarm.
Clearing System StatusPress the SYSTEM STATUS button, listen to the status message, then disarm the system to clear system status. If the trouble condition was a low system battery, perform a sensor test. The SYSTEM STATUS button should turn off if all trouble conditions have been corrected.
Testing
Note
The RF Electronic Thermostat is automatically tested when a sensor test begins. The panel will announce, Sensor XXX activated, status is one, if the thermostat is OK.
As an added safeguard, there are system tests you should do yourself on a regular basis. It is recommended that you test your system weekly.
Testing SensorsYou can test sensors one at a time to make sure they are sending strong signals to the panel. You should test the security system at least once a week.
To perform the sensor test:1.Open the panel Cover.
2.Enter the master access code.
3.Press the Test button once. The panel will announce Sensor Test.
4.Press the DONE button.
The panel will voice prompt you with a list of your programmed sensors that you need to test. The panel will start with sensor 1 and announce Test sensor 1, sensor name.
When you trip a sensor and it communicates successfully it will be removed from the list. You may trip the sensors in any order.
After all sensors have been successfully tested, the panel will announce Sensor test complete, press DONE. Press DONE. The panel will announce Sensor test ok.
If any of the sensors did not test successfully and you want to terminate the test, press DONE or Cancel. The panel will announce Sensor test canceled or failure. If a sensor test fails, call your security dealer.
Use the following table to trip devices:
Device | Do This |
|
|
Door/Window Sensor | Open the secured door or window. |
|
|
Freeze Sensor | Apply ice to the sensor. Do not allow the sensor to get |
| wet. |
|
|
Water Sensor | Press a wet rag or wet finger over both of the round, |
| |
|
|
Carbon Monoxide Sensor | Unplug the CO Alarm. Plug it back in, then press the |
| TEST/RESET button until the unit beeps 8 times. |
|
|
Glass Guard Sensor | Tap the glass 3 or 4 inches (8 cm) from the sensor. |
|
|
Motion Sensor | Avoid the Motion Sensor’s view for 5 minutes, then |
| enter its view. |
|
|
Rub your hands together until warm, then place one | |
tor | hand on the detector for 30 seconds. |
|
|
24 | Security Pro 1000 |