Removing and replacing the doors.

Removing and replacing the doors.

When installing or moving the refrigerator, the doors may need to be removed in order to fit the refrigerator through a doorway.

Removing the Doors

Make sure the doors are closed and the refrigerator is unplugged.

Disconnect water line and wiring harness.

 

Near the lower hinge on the freezer side, push in on the

 

collars at each end of the coupling, and pull the water

 

line tubing from the coupling. Also, disconnect wiring

Wire Harness

harness. Pull the water line and the harness through the

 

lower rail.

Collars

Remove the hinge covers and the hinges.

 

In order to access the hinges, the hinge covers need to be

 

removed. Remove the cover by grasping it on the sides,

 

near the back of the cover. Push back on the cover and

 

lift up at the back, then the front.

Hinge Cover

 

NOTE: DO NOT use a screwdriver to remove the cover. BE CAREFUL

 

not to break the rear retaining tab on the hinge cover. Remove the

 

hinges using a Torx T-20.

 

Remove the doors.

 

Carefully rotate the door to 90°. Guiding the disconnected

 

water line and wiring harness, lift the door straight up.

 

NOTE: Not lifting the door straight up may damage the bottom hinge.Place doors on a protected surface.

NOTE: Be careful not to pinch the water tubing and the wire harness at the bottom of the door.

NOTE: Do not allow the connector to contact the floor. Hard contact can damage the connector. See “Replacing the Doors.”

90

Door

Safety Instructions Operating Instructions Installation Instructions

Replacing the Doors

Place doors on bottom hinges.

With the door at 90°, lower the door straight down onto the bottom hinge. Carefully close the door.

NOTE: Not lowering the door straight down onto the bottom hinge may damage the hinge.

NOTE: Do not allow the connector to contact the floor. Hard contact can damage the connector.

Removing the Doors Replace top hinges and hinge covers.

Reinstall the top hinges using a Torx T-20. Replace the hinge covers. If the doors are not level, adjust the bottom right hinge with a 7/16″ open ended wrench.

Reconnect water line and wiring harness.

Insert water tubing back into coupling, making sure the tubing is pushed far enough into the coupling so that you no longer see the mark on the tubing. Reconnect the wiring harness.

Make sure the doors are closed and the refrigerator is unplugged. Turn on the water supply and plug the refrigerator back in.

hinges using a Torx T-20.NOTE: Not lifting the door straight up may damage the bottom hinge. Hinge Pin

Connector

23

Troubleshooting Tips Consumer Support

Page 23
Image 23
GE 200D2600P010 Removing and replacing the doors, Safety Instructions Operating Instructions Installation Instructions