Manufacturedfor : General Electric Company, Louisville, KY 40225
EPAEST. No. 070595-MN-001

Performance Data Sheet

SmartWater Filtration System
MWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
StandardNo.42: AestheticEffects
Parameter USEPA Influent Influent Effluent % Reduction Min.Required
MCL ChallengeConcentration Average Average Maximum Average Minimum Reduction
Chlorine 2.0mg/L+ 10% 1.96 mg/L 0.06mg/L 0.11mg/L 96.77% 94.74% > 50%
T& O —— —
Particulate** ≥ 10,000particles/mL 6,400,000 #/mL 58,833#/mL 150,000#/mL 99.14% 97.97% ≥ 85%
StandardNo.53: HealthEffects
Parameter USEPA Influent Influent Effluent %Reduction Min.Required
MCL ChallengeConcentration Average Average Maximum Average Minimum Reduction
Turbidity 0.5NTU 11 + 1 NTU*** 10.5 NTU 0.14 NTU 0.28 NTU 98.54% 97.20% 0.5 NTU
Cysts ≥99.95%Reduction Minimum50,000L 118,750#/L <1 #/L 4 #/L > 99.99% > 99.99% ≥ 99.95%
Asbestos ≥ 99% Reduction 107to 108fibers/L;> 10µm 57 MF/L 0.996MF/L < 1 MF/L 99.60% 99.39% ≥ 99%
LeadatpH 6.5 0.015mg/L 0.15 mg/L+ 10% 0.1567mg/L < 0.001mg/L <0.001 mg/L 99.36% 99.29% 0.010mg/L
LeadatpH 8.5 0.015mg/L 0.15 mg/L+ 10% 0.1433mg/L < 0.001mg/L <0.001 mg/L 99.30% 99.29% 0.010mg/L
Mercuryat pH 6.5 0.002mg/L 0.006mg/L + 10% 0.0059mg/L 0.000350 mg/L 0.0007mg/L 94.70% 87.50% 0.002mg/L
Mercuryat pH 8.5 0.002mg/L 0.006mg/L + 10% 0.0057mg/L 0.000325 mg/L 0.0006mg/L 93.20% 89.29% 0.002mg/L
Alachlor 0.002 mg/L 0.04mg/L+ 10% 0.0367mg/L 0.00023mg/L 0.0004mg/L 99.34% 98.67% 0.002mg/L
Lindane 0.0002mg/L 0.002mg/L+ 10% 0.0020mg/L <0.00002mg/L < 0.00002mg/L 99.00% 98.95% 0.0002mg/L
2,4-D 0.070mg/L 0.210mg/L+ 10% 0.2033mg/L 0.00337mg/L 0.011000mg/L 98.32% 94.50% 0.070mg/L
Toxaphene 0.003mg/L 0.015mg/L+ 10% 0.0160mg/L 0.00100mg/L 0.001000mg/L 93.44% 91.67% 0.003mg/L
Benzene 0.005mg/L 0.015mg/L+ 10% 0.0145mg/L 0.000500mg/L 0.000500mg/L 96.51% 95.83% 0.005mg/L
Carbofuran 0.040mg/L 0.080 mg/L+ 10% 0.0830mg/L 0.001000mg/L 0.001000mg/L 98.78% 98.65% 0.04mg/L
1,4dichlorobenzene
0.075mg/L 0.225 mg/L+ 10% 0.2283mg/L 0.000500mg/L 0.000500mg/L 99.78% 99.77% 0.075mg/L
Atrazine 0.003mg/L 0.009mg/L + 10% 0.0087mg/L < 0.0005mg/L < 0.0005mg/L 94.22% 93.33% 0.003mg/L
* Tested using a flow rate of 0.50 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity units

Operating Specifications

Capacity:certified forup to 300 gallons (1135l); up to six months formodels without a replacementfilter indicatorlight;
up toone year for models witha replacement filterindicator light
Pressure requirement:40–120 psi (2.8–8.2 bar), non-shock
Temperature: 33–100ºF (0.6–38ºC)
Flow rate: 0.5 gpm (1.9 lpm)

General Installation/Operation/Maintenance Requirements

Flush new cartridge at full flow for 3 minutes to purge out trapped air.
Replace cartridge when the indicator light flashes or water flow rate is reduced on non-indicator units.

Special Notices

Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
Thisdrinking watersystem mustbe maintainedaccordingto manufacturer’sinstructions,includingreplacementof filter cartridges.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water treatmentsystem are not necessarily in your water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be
installed and operated in accordance with manufacturer’s recommended procedures and guidelines.
NSF
®
System Testedand Cer tified by NSF International against ANSI/NSF Standard42 & 53 for the reduction of:
StandardNo. 42: Aesthetic Effects
Chemical Unit
Chlorine Tasteand Odor
Mechanical Filtration Unit
Particulate Reduction, Class I
StandardNo. 53: Health Effects
Chemical ReductionUnit
AlachlorandAtrazine Reduction
Benzene and CarbofuranReduction
1,4 dichlorobenzeneand 2,4-D Reduction
Lead and Lindane Reduction
Mercuryand Toxaphene Reduction
Mechanical Filtration Unit
TurbidityReduction
Cyst and Asbestos Reduction