Manufacturedfor : General Electric Company, Louisville, KY 40225

Performance Data Sheet

SmartWater Filtration System
GSWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
StandardNo.42: AestheticEffects
Parameter USEPA Influent InfluentChallenge Effluent % Reduction Min.Required
MCL Average Concentration Average Maximum Average Minimum Reduction
Chlorine 1.845mg/L 2.0mg/L+10% < 0.05 mg/L 0.05mg/L >97.29% 96.43% >50%
T& O —— — ———
Particulate** 143,333#/mL
atleast 10,000particles/mL
29.83#/mL 140 #/mL 99.98% 99.91% > 85%
StandardNo.53: HealthEffects
Parameter USEPA Influent
InfluentChallenge
Effluent % Reduction Min. Required
MCL Average Concentration Average Maximum Average Minimum Reduction
Turbidity 1 NTU*** 10.3NTU*** 1+1 NTU*** 0.106NTU 0.14NTU 98.97% 98.61% 0.5NTU
Cysts
99.95%Reduction
200,000#/L
Minimum50,000L
00>99.99% > 99.99% > 99.95%
Leadat pH 6.5 0.015mg/L 0.15 mg/L 0.15mg/L+10% < 0.001mg/L <0.001mg/L > 99.33% > 99.33% 0.010mg/L
Leadat pH 8.5 0.015mg/L 0.14 mg/L 0.15mg/L+10% 0.001mg/L 0.003 mg/L > 99.29% 97.86% 0.010mg/L
Lindane
0.0002mg/L
0.0216mg/L 0.002mg/L+10%
<0.00002mg/L <0.00002 mg/L
99.07% 98.75% 0.0002mg/L
Atrazine
0.003mg/L
0.008mg/L 0.009mg/L+10% < 0.002mg/L <0.002mg/L > 76.12% > 66.67% 0.003mg/L
* Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity units

Operating Specifications

Capacity:certified forup to 750 gallons (2,838l); up to six months
Pressure requirement: 40–120 psi (2.8–8.2 bar)
Temperature: 33–100ºF (0.6–38ºC)
Flow rate: 0.5 gpm (1.9 lpm)

General Installation/Operation/Maintenance Requirements

Flush new cartridge at full flow for 3 minutes to purge out trapped air.
Replace cartridge when flow becomes too slow.

Special Notices

Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter
cartridges.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water treatmentsystem are not necessarily in your water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems
must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines.
NSF
®
System tested and certified by NSF International against Standard 42 for the reductionof
chlorine, taste and odor,particulate Class I and Standard 53 for the reduction of cyst, lead,
Lindane, Atrazine and turbidity.