Performance Data SheetSmartWater Filtration System-GE®MWF Cartridge

This system has been tested and certified in filter model GE MWF according to NSF/ANSI Standards 42 and 53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.* (Safety factors built in for unmetered usage)

Standard No. 42: Aesthetic effects

Substance

 

NSF Specified Challenge

Average %

Average Product

Max Permissible Product

NSF Reduction

NSF Test

Reduction

Average Influent

Concentration

Reduction

Water Concentration

Water Concentration

Requirements

Report

Chlorine Taste

2.0 mg/L

2.0mg/L ± 10%

97.5%

0.05 mg/L

N/A

≥50%

J-00077703

& Odor

 

 

 

 

 

 

 

Nominal Particulate

7,833,333 pts/mL

At least 10,000 particles/mL

99.7%

18,617 pts/mL

N/A

≥85%

J-00077704

Class I, ≥0.5 to <1.0 μm

 

 

 

 

 

 

 

Standard No. 53: Health effects

Substance

 

NSF Specified Challenge

Average %

Average Product

Max Permissible Product

NSF Reduction

NSF Test

Reduction

Average Influent

Concentration

Reduction

Water Concentration

Water Concentration

Requirements

Report

Cyst*

147,5000 cysts/L

Minimum 50,000 cysts/L

99.99%

1 cyst/L

N/A

≥99.95%

J-00077721

Asbestos

47 MF/L

7

8

>99%

<1 MF/L

N/A

≥99%

J-00077707

10 to 10 fibers/L; fibers

 

 

greater than 10 μm in length

 

 

 

 

 

Atrazine

0.009 mg/L

0.009 mg/L ± 10%

94.5%

0.0005 mg/L

0.003 mg/L

N/A

J-00077708

Benzene

0.016 mg/L

0.015 mg/L ± 10%

96.7%

0.0005 mg/L

0.005 mg/L

N/A

J-00077717

Carbofuran

0.08 mg/L

0.08 mg/L ± 10%

98.7%

0.001 mg/L

0.04 mg/L

N/A

J-00077718

Endrin

0.006 mg/L

0.006 mg/L ± 10%

95.6%

0.0003 mg/L

0.002 mg/L

N/A

J-00082185

Lead @ pH 6.5

0.152 mg/L

0.15 mg/L ± 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00077722

Lead @ pH 8.5

0.148 mg/L

0.15 mg/L ± 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00077723

Lindane

0.002 mg/L

0.002 mg/L ± 10%

99%

0.00002 mg/L

0.0002 mg/L

N/A

J-00077726

Mercury @ pH 6.5

0.0058 mg/L

0.006 mg/L ± 10%

93.2%

0.0004 mg/L

0.002 mg/L

N/A

J-00077727

Mercury @ pH 8.5

0.0061 mg/L

0.006 mg/L ± 10%

93.2%

0.0004 mg/L

0.002 mg/L

N/A

J-00077728

P-Dichlorobenzene

0.222 mg/L

0.225 mg/L ± 10%

99.7%

0.005 mg/L

0.075 mg/L

N/A

J-00077729

Tetrachloroethylene

0.015 mg/L

0.015 mg/L ± 10%

96.6%

0.0005 mg/L

0.005 mg/L

N/A

J-00082184

Toxaphene

0.015 mg/L

0.015 mg/L ± 10%

93.2%

0.001 mg/L

0.003 mg/L

N/A

J-00077730

2, 4-D

0.218 mg/L

0.210 mg/L ± 10%

99.5%

0.0009 mg/L

0.07 mg/L

N/A

J-00077705

*Based on the use of Cryptosporidium parvum oocysts

Capacity 300 gallons (1,135 liters). Contaminant reduction determined by NSF testing.

Application Guidelines/Water Supply Parameters

Service Flow

0.5 gpm (1.9 lpm)

Water Supply

Potable Water

Water Pressure

40–120 psi (2.8–8.2 bar)

Water Temperature

33ºF–100ºF (0.6ºC–38ºC)

It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised. See Installation Manual for Warranty information.

Operating Specifications

Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock

Temperature: 33–100°F (0.6–38°C)

Flow rate: 0.5 gpm (1.9 lpm)

General Installation/Operation/Maintenance Requirements

trapped air.

• expected to drop below 33°F (1°C). Do not install systems in areas where ambient temperatures may go above 100ºF or below 40°F. Do not install on a hot water supply.

Special Notices

Installation instructions are included with the product when shipped.

This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.

Check for compliance with the applicable state and local laws and regulations.

Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines.

Installation and use MUST comply with all state and local plumbing codes. Do not install if water pressure exceeds 120 psi. If your water pressure exceeds 80 psi (552 kPa), you should install a pressure-limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.

Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.

controlling pressure due to thermal expansion must be installed.

Tested and Certified by NSF International against ANSI/NSF Standards 42 and 53 in model GE MWF for the reduction of:

Standard No. 42: Aesthetic Effects

• Mechanical Filtration

Standard No. 53: Health Effects

 

• Chemical

• Chemical Reduction

– Lead and Lindane Reduction

– Chlorine Taste and Odor

– Particulate Reduction, Class I

– Atrazine Reduction

– Mercury and Toxaphene Reduction

 

 

– Endrin Reduction

• Mechanical Filtration

 

 

– Benzene and Carbofuran Reduction

– Cyst and Asbestos Reduction

GE

 

– 1,4 Dichlorobenzene and

 

 

2,4-D Reduction

 

Appliances

 

 

 

Appliance Park

 

 

 

Louisville, KY 40225

 

REPLACEMENT

geapplianceparts.com

 

ELEMENT

 

 

© 2010 GE Company PC61278B