Setting the Chlorine Generator/Salt Check (conditioner only)

The controller has the capability to produce a low level of chlorine during the brine draw stage of regeneration. It can also sense if there is any brine present during the time when brine draw is occurring. This parameter can be adjusted to the following:

0 = Chlorine Generator with Salt Check disabled

1 = Chlorine Generator with Salt Check enabled

2 = Salt Check only

A refill sensor probe kit (P/N 3002122) must be installed for this function to work properly. After it is installed, select the desired parameter and push SET to accept the selection.