UltraMax System Configurations

Upon initial start-up of the UltraMax controller, the software will request a pre-determined model number. This model number populates the default values within the controller, allowing for quick and easy set-up of the software without entering several levels of data. The table below shows the pre-determined model numbers for the controller and the associated primary valve functions for each number.

Use the UP and DOWN buttons to scroll through the available model numbers. Press the SET button to select the number and move to the standard programming value.

Model

System Description

Operation

System

Salt

Number

Type

Capacity

Amount

 

 

 

 

 

 

 

 

 

 

 

10

1.0 cu ft Conditioner

268 Valve

15 Kgrains

3.0 lbs

 

 

 

 

 

15

1.5 cu ft Conditioner

268 Valve

23 Kgrains

4.5 lbs

 

 

 

 

 

20

2.0 cu ft Conditioner

268 Valve

31 Kgrains

6.0 lbs

 

 

 

 

 

93

Generic Filter

263 Valve

N/A

N/A

 

 

 

 

 

98

Generic Conditioner

268 Valve

25 Kgrains

9.0 lbs

 

 

 

 

 

Controller Reset:

If the incorrect model number is accidentally selected for the controller, you can easily reset the controller to the factory default mode. When the controller is in normal operating mode showing the time of day, perform the following steps.

1.Press the DOWN and SET buttons simultaneously and hold for 5 seconds.

2.After 5 seconds the controller will go blank. Release the buttons and the controller will scroll "MODEL NUMBER " and the selected model will be displayed.

3.If the number is correct, wait 30 seconds and the controller will automatically go back to normal operation mode.

4.If the model number is incorrect, press and hold the SET button for 5 seconds. This will default the controller back to the factory default setting. The controller will scroll "MODEL NUMBER " and the factory model number will begin flashing, meaning it can be changed. USe the UP or DOWN buttons to scroll to the correct model number. Select that number by pressing the SET button.

UltraMax System Configurations

43

 

Rev A

Page 43
Image 43
GE 263, 268 manual UltraMax System Configurations, Controller Reset