Device | Test Procedure | Touchpad Result(s) |
|
|
|
Touchpad | Trip a: |
|
| • | Touchpad Panic POLICE OK |
| Police panic alarm, |
|
| • | Touchpad Panic FIRE OK |
| Fire panic alarm, and |
|
| ||
| Auxiliary panic alarm. |
|
| • | Touchpad Panic AUXILIARY OK |
|
|
|
| • | POLICE PANIC OK |
|
|
|
| • | FIRE PANIC OK |
|
|
|
| • | AUXILIARY PANIC OK |
|
|
|
|
|
|
Wireless Touchpad | Press the Bypass key. |
|
| • | Zones nn OK |
|
|
|
| • | TOUCHPAD nn OK |
|
|
|
|
|
|
Keychain Touchpad | Press and hold the Lock | and Unlock | buttons | • | Zones nn OK |
| simultaneously for 3 seconds. |
| • | TOUCHPAD nn OK | |
|
|
|
|
|
|
| Press and hold the Star | and Light | buttons | • | Touchpad Panic AUXILIARY OK |
| simultaneously for 3 seconds. |
| • | AUXILIARY PANIC OK | |
|
|
|
| ||
Panic button | Press and hold the appropriate panic button(s) for 3 | • | Zones nn OK | ||
| full seconds. |
|
| • | SENSOR nn OK |
|
|
|
| ||
|
|
|
|
| |
Door/window sensor | Open the secured door or window. |
| • | Zones nn OK | |
|
|
|
| • | SENSOR nn OK |
|
|
|
| ||
Smoke detector | Press and hold the test button until the system sounds | • | Zones nn OK | ||
| transmission beeps. |
|
| • | SENSOR nn OK |
|
|
|
| ||
|
|
|
| ||
Motion detector | Avoid the motion detector view for 5 minutes, then | • | Zones nn OK | ||
| enter its view. |
|
| • | SENSOR nn OK |
|
|
|
| ||
|
|
| |||
• | Zones nn OK | ||||
tor (Not UL investigated) | hand on the detector for 30 seconds. |
| • | SENSOR nn OK | |
|
|
|
| ||
|
|
|
| ||
Shock sensor | Tap the glass twice, away from the sensor. Wait at | • | Zones nn OK | ||
(Not UL investigated) | least 30 seconds before testing again. |
| • | SENSOR nn OK | |
|
|
|
| ||
|
|
|
| ||
Phone Interface and | Activate a Police panic by accessing the system using | • | POLICE PANIC OK | ||
Voice Module | the phone and pressing * + * + * + * + * + *. |
|
| ||
Glass guard sensor | Tap the glass 3 or 4 inches from the sensor. | • | Zones nn OK | ||
(Not UL investigated) |
|
|
| • | SENSOR nn OK |
|
|
|
| ||
|
|
|
| ||
Freeze sensor | Apply an ice cube wrapped in plastic to the sensor. Do | • | Zones nn OK | ||
(Not UL investigated) | not allow the sensor to get wet. |
| • | SENSOR nn OK | |
|
|
|
|
•If you need more time to complete testing, restart the timer by pressing 8 + CODE + 3.
•Check to see that all sensors have been tested by pressing *. Touchpads display a list of untested sensors.
•You will know that you have finished testing when touchpads display, “SENSOR TEST OK” or “ZONES ALL TESTED.”
4.Disarm to Level
The purpose of this test is to verify communication between the central monitoring station and your system.
Most phone tests take only a few minutes, however, your system will try for up to 15 minutes to establish a connection if necessary.
38 | Concord 4 Series Security Systems |