3.The touchpad displays “REGULAR USER CODES” or “REG CODES.” Press B until the display reads “SYSTEM MASTER CODE” or “SYS MASTER,” then press #.

4.Replace the existing code with the new 4 digit System Master Code then press #.

5.Press * + 00 + # to exit the programming menus.

Using Programming Shortcuts

A programming shortcut is a number that “jumps” you to a particular spot in the programming menus.

A series of shortcut numbers takes you directly to the feature or code you want to change.

1.Enter User Programming.

Local Phone

# + 9 + CODE

 

 

Remote Phone Access

Dial the phone number + # + CODE + # + 9 + CODE

 

 

Touchpad

9 + CODE

 

 

2.Enter a programming command sequence.

Time

 

* + 020 + TTTT + #

 

Date

 

* + 021 + DDMMYY + #

 

 

 

 

 

Regular User Codes

Concord 4

 

Concord Express V4

 

User 00: * + 0300000 + NNNN + # [* + 030000 + NNNN + #]

 

User 01: * + 0300010 + NNNN + # [* + 030001 + NNNN + #]

 

User 02:

* + 0300020 + NNNN + # [* + 030002 + NNNN + #]

 

(continues up to User 229)

(continues up to User 15)

 

User 229: * + 0302290 + NNNN + #

 

 

If using alphanumeric or fixed display touchpads, use A and B to scroll

 

through the code attributes and change them as required.

Partition Master Codes

Partition 1:* + 0310 + NNNN + #

 

(Concord 4 systems only)

Partition 2:* + 0311 + NNNN + #

 

 

Partition 3:* + 0312 + NNNN + #

 

 

Partition 4:* + 0313 + NNNN + #

 

 

Partition 5:* + 0314 + NNNN + #

 

 

Partition 6:* + 0315 + NNNN + #

 

 

 

 

 

System Master Code

 

* + 0320 + NNNN + #

 

Direct Bypassing Attribute

 

* + 030NNN1 + 1(off) or 2(on) + # (nnn = user no.)

 

 

* + 030NN1 + 1(off) or 2(on) + # (Concord Express V4)

 

 

 

Remote Access Attribute

 

* + 030NNN2 + 1(off) or 2(on) + # (nnn = user no.)

 

 

* + 030NN2 + 1(off) or 2(on) + # (Concord Express V4)

System Test Attribute

 

* + 030NNN3 + 1(off) or 2(on) + # (nnn = user no.)

 

 

* + 030NN3 + 1(off) or 2(on) + # (Concord Express V4)

 

 

 

Latchkey Report Attribute

 

* + 030NNN4 + 1(off) or 2(on) + # (nnn = user no.)

 

 

* + 030NN4 + 1(off) or 2(on) + # (Concord Express V4)

Partition Assign Attribute

 

* + 030NNN5 + desired partitions 1-6 + # (nnn = user no.)

(Concord 4 systems only)

 

 

 

 

 

 

Downloading

 

* + 041 + 1(off) or 2(on) + #

Touchpad Brightness

 

* + 043 + 0 through 3 + #

 

 

 

 

 

Volume

 

* + 044 + 0 through 7 + #

 

Voice Chime

 

* + 045 + 1(off) or 2(on) + #

 

 

 

 

Concord 4 Series Security Systems

57