2.Enter a programming command sequence. (continued)
Output 3 | Attaching schedules for Output 3 operation: | |
| Sched 0: | * + 065200 + 1(off) or 2(on) + # |
| Sched 1: | * + 065201 + 1(off) or 2(on) + # |
| (Continues through Schedule 15) | |
| Sched 15: * + 065215 + 1(off) or 2(on) + # | |
|
| |
Output 4 | Attaching schedules for Output 4 operation: | |
| Sched 0: | * + 065300 + 1(off) or 2(on) + # |
| Sched 1: | * + 065301 + 1(off) or 2(on) + # |
| (Continues through Schedule 15) | |
| Sched 15: * + 065315 + 1(off) or 2(on) + # | |
|
| |
Output 5 | Attaching schedules for Output 5 operation: | |
| Sched 0: | * + 065400 + 1(off) or 2(on) + # |
| Sched 1: | * + 065401 + 1(off) or 2(on) + # |
| (Continues through Schedule 15) | |
| Sched 15: * + 065415 + 1(off) or 2(on) + # | |
|
| |
Output 6 | Attaching schedules for Output 6 operation: | |
| Sched 0: | * + 065500 + 1(off) or 2(on) + # |
| Sched 1: | * + 065501 + 1(off) or 2(on) + # |
| (Continues through Schedule 15) | |
| Sched 15: * + 065515 + 1(off) or 2(on) + # | |
|
| |
Arm to AWAY | Attaching schedules for Arming to AWAY operation: | |
| Sched 0: | * + 066000 + 1(off) or 2(on) + # |
| Sched 1: | * + 066001 + 1(off) or 2(on) + # |
| (Continues through Schedule 15) | |
| Sched 15: * + 066015 + 1(off) or 2(on) + # | |
|
|
|
Energy Saver | Setpoints |
|
| Low: | * + 070 + NN + # |
| High: | * + 071 + NN + É |
|
| (enter temperature value in Fahrenheit) |
|
|
|
Factory Code |
| * + 010 |
|
|
|
System Number |
| * + 011 |
System Level |
| * + 012 |
|
|
|
Software Version |
| * + 013 |
Attach Lights to Sensors | Attaching schedules for Arming to AWAY operation: | |
| Light 1: | * + 080 + NN + # (nn = sensor no. to be attached) |
| Light 2: | * + 081 + NN + # (nn = sensor no. to be attached) |
| (Continues through Light 9) | |
| Light 9: | * + 088 + NN + # (nn = sensor no. to be attached) |
|
|
|
Exit | * + 00 + # |
|
|
|
|
60 | Concord 4 Series Security Systems |