Manuals
/
GE
/
Household Appliance
/
Air Conditioner
GE
4100, 6100 manual GE Zoneline packaged terminal air conditioners
Models:
4100
6100
1
1
60
60
Download
60 pages
8.22 Kb
1
2
3
4
5
6
7
8
<
>
Specs
Install
Typical 4100 Series, 230/208-VoltWiring Diagram
Replacements of Existing Ducted Units
Warranty
Dimension
CDC Terminal Location and Typical Wiring
Compressor Restart Delay
Series Heat Pump with Backup Electric Heat
Auxiliary Control Settings
Page 1
Image 1
GE Zoneline
®
packaged terminal air conditioners
2010 contract sales architects and engineers data manual
Page 2
Page 1
Image 1
Page 2
Contents
GE Zoneline packaged terminal air conditioners
6100 Series Heat Pump with Backup Electric Heat
ALL UNITS REQUIRE POWER CONNECTION KIT
Quick Reference
Full Specs on pages 52 and
Zoneline Chassis Nomenclature
Power Connection Kits
230/208-VoltLine Cord Connection Units
265-Volt Sub-Baseand Direct Connected Units
Cooling With Resistance Heat
Deluxe Dry Air 25 Models
Features and Benefits
Table of Contents
Installation and Dimensions
Product Specifications
Deluxe Line Optional Features
Deluxe Line Standard Features
Introduction
Advantages of the GE Zoneline System
The Zoneline System
Optional Accessories of the Zoneline System
Resistance heat
Zoneline Features
Heat pump
41 Series
Standard Physical Dimensions
Features and Benefits
Highly Featured Microprocessor Controls
Quick Heat Recovery - Heat Pump Units
Fan-CycleSwitch - “SmartFan”
Fan-OnlySetting - HIGH/LOW
Compressor Restart Delay
Electronic Temperature Limiting
Concealed Manual Vent Control
Up-FrontAir Filters
Corrosion Protection Optional
Internal Condensate Removal ICR
Auxiliary Control-AuxSet Button
Auxiliary Control Settings
To change modes
Temperature limits—Cool
Auxiliary Control Settings cont
Central Desk Control
CDC Terminal Location and Typical Wiring
Important CDC Comments all series applicable
Switch
Remote Thermostat Control
Field Wiring Terminal
Resistance Heat Models
RAK806 Universal Control Cover Label
Field Wiring Terminal
Heat Pump Models
Feature
Remote Thermostat Control
Type
Zoneline Series
Function
Thermostat Model
Balance Point
Heat Pumps and Energy Savings
Zoneline Heat Pump Heat Source Logic
Heat Pump Operation - Zoneline 6100 Series
Heat pump defrost - Zoneline 6100 Series
Heat pump condensate
Air Distribution
Application Comments
High Wall Mount - For units
WALL CASE WITH CHASSIS INSTALLED
Dimensions
RAB71A WALL CASE
RAB77 WALL CASE
Sub-Base
Wall Case
Sub-BaseContinued
Wall Case Installation Data
General
Sub-basesfor the 265-voltunits
Wall Case Installation Data Continued
Architectural Window Louver Installation
Window, Curtain and Panel Wall Construction
Masonry Wall Construction
Refer to page 43 for maximum power cord length
Case Angles
FASTENING WALL CASE
FRAMING FOR WALL CASE
Brick Veneer and Frame Construction
Frame and Brick Veneer Installation
WALL SECTION - DETAILED SIDE VIEW
Cord set connected
Cord Set Connected
WALL SECTION - DETAILED SIDE VIEW
Sub-BaseConnected
ROOM
TOP VIEW
WALL CASE INSTALLATION - CORD SET CONNECTED
FRONT VIEW
6-1/4± 1/4
A B C
1/4 See note
RAB71A/77 Wall Case
Condensate Disposal Systems
Temperature-ActivatedDrain Valve
Cooling Condensate
Slinger Ring Systems
External Drain. See page 36 for internal drain
WALL CASE WITH RAD10 DRAIN KIT
Internal Drain. See page 35 for external drain
WALL CASE WITH RAD10 DRAIN KIT
SCREWS
“A” “B”
New Ducted Installations
Ducted Installations
Replacements of Existing Ducted Units
Ducted Application Considerations
Page
See page 38 for all notes Sub-BaseInstallation
Line Cord Installation
RAG60 Outdoor Grille
Exterior Grilles
RAG61 Outdoor Grille
RAG63 - Bittersweet Chocolate
and Special Outdoor Grilles
Exterior Architectural Treatments
230/208-VoltPermanently Connected Units
230/208-Volt Line-CordConnected Units
230/208 Volt Sub-Baseand Direct-ConnectedUnits
265 Volt Sub-Baseand Direct-ConnectedUnits
Replacement of Existing Chassis
Electrical Wiring Information - 4100/6100 Series
Essential Elements Ordering Overview
230/208-Voltand 265-VoltUnits
Latent System Capacity
Maximum Connected Load
265-VoltUnits
230/208-Volt Line-CordConnected Units
Outdoor Design Temperature Difference
Normal Yearly Operating Data
Typical 4100 Series, 230/208-VoltWiring Diagram
Typical 4100 Series, 230/208-Volt
Schematic Diagram
Typical 6100 Series, 230/208-VoltWiring Diagram
Schematic Diagram
Typical 6100 Series, 230/208-Volt
Suggested Bid Form Specifications
Alternate specification for molded wall case
Suggested Bid Form Specifications continued
Specifications for Sub-Baseif required
A Z 6 1 H 1 2 D A D
Receptacles/Sub-Bases
Zoneline Chassis Nomenclature
Tandem
Preliminary Specifications
Kit Number
Complete Accessory List
Description
Electrical Wiring Installation
General Installation Suggestions
Central Desk Control and Remote Thermostat Wiring
Wall Case/Exterior Grille
What is covered
Zoneline Warranty
Ducted Installation Comments
Replacement Installations
Page
Page
Exterior Grille Color Samples
Alphabetical Index
Category
GE has a policy of continuous improvement