38
DUCTED APPLICATION (AZ2500/2800/2900/3500/3800/3900/4100/6100 SERIES)
44"
RAK6052
ADAPTER
TRANSITION
Notes:
1.RAK6052 kit includes duct adapter, transition and mounting hardware.
2.RAK601 duct extension may be installed at either end of the RAK6052 duct adapter. Maximum duct extension length is 15'. Duct extension must be field fabricated for installations where length of duct exceeds length of RAK601 (44").
3.Ducted units may need to be permanently connected. Check local code for specific electrical installation requirements.
4.Duct extension kit RAK601 contains 44" duct extension, discharge grille mounting collar, and discharge grille. Duct extension must be cut to required length. Two ducted installations may be made from one kit if the combined ducted length is less than 44". RAK602 kit contains mounting collar, discharge grille and mounting hardware necessary for second installation.
5.Filler strip (field supplied) actual width depends upon wall case projection into room. A flush installation to finished wall (i.e., no filler strip) can be made.
6.Unit must be installed to provide at least a 2" clearance between side of unit and wall.
7.Provisions for return air must be made in order to allow air circulation from secondary room. Doors in both secondary and primary rooms may be undercut or a return grille may be installed through common wall.
8.For replacement of
RAK601
44" LENGTH
8" high
7 | 3/8" |
- | |
| wide |
RECOMMENDED MINIMUM CLEARANCE
2" TO SIDE WALL