Zoneline® Features

 

Resistance heat

Heat pump

 

AZ

AZ

AZ

 

41 Series

41 Dry Air 25

61 Series

Cooling EER Range (230 Volts/265 Volts)

10.6 - 12.8

11.3 - 12.2

11.2 - 13.2

 

 

 

 

Heating COP Range (230 Volts/265 Volts)

N/A

N/A

3.3 - 4.0

Refrigerant type

R-410A

R-410A

R-410A

 

 

 

 

Cross-flow (tangential) blower

Standard

Standard

Standard

 

 

 

 

Enhanced Dehumidification

Optional

Standard

—

 

 

 

 

Heat pump with resistance heat back-up

—

—

Standard

 

 

 

 

Heat pump with supplemental resistance heat

—

—

Standard

Staged Heating

—

—

3-Stage***

 

 

 

 

Universal heaters - UPC**

Standard

Standard

Standard

 

 

 

 

Tactile touch pad controls with LED

Standard

Standard

Standard

 

 

 

 

Touch control set-up features

Standard

Standard

Standard

 

 

 

 

Highly featured microcomputer controls

Standard

Standard

Standard

Electric resistance heat lock-out (above 46°F)

—

—

Standard

 

 

 

 

Automatic emergency heat

Standard

Standard

Standard

 

 

 

 

Heat pump defrost system

—

—

Reverse cycle

 

 

 

 

High-Temperature Operation Protection

—

—

Standard

 

 

 

 

Quick heat recovery

—

—

Standard

 

 

 

 

Temperature Boost

—

—

Selectable

Separate Indoor & Outdoor

AC

AC

DC

Motors — Permanently Lubricated

 

 

 

 

 

 

 

2-Speed Outdoor Fan

Standard

Standard

Standard

 

 

 

 

Indoor fan speed settings

Hi/Low

Hi/Low

Hi/Low

Fan Only setting—2-speed

Hi/Low

Hi/Low

Hi/Low

Cool & heat only settings

Hi/Low/Auto

Hi/Low/Auto

Hi/Low/Auto

 

 

 

 

“SmartFan” Fan Cycle Control

Standard

Standard

Standard

 

 

 

 

Auto power recovery

Standard

Standard

Standard

 

 

 

 

Automatic Compressor Restart Delay

Standard

Standard

Standard

 

 

 

 

Freeze Sentinel™ (41F)

Standard

Standard

Standard

Heat Sentinel (85F)

Standard

Standard

Standard

 

 

 

 

Automatic indoor frost control

Standard

Standard

Standard

 

 

 

 

Temperature limiting

Electronic 7-step

Electronic 7-step

Electronic 7-step

 

 

 

 

Solid-state thermostat

Standard

Standard

Standard

 

 

 

 

Remote thermostat compatibility

Standard

Standard

Standard

Central desk control compatibility

Standard

Standard

Standard

 

 

 

 

2-position discharge grille 50º/40º

Standard

Standard

Standard

 

 

 

 

Upfront filter (interchangeable)

Standard

Standard

Standard

 

 

 

 

3-position manual air vent control

Standard

Standard

Standard

 

 

 

 

Sleep function

Standard

Standard

Standard

 

 

 

 

Transfer Fan Connections

Standard

Standard

Standard

Ducted Installation Capability

Optional

Optional

Optional

 

 

 

 

Corrosion-treated chassis

Optional

Standard

Optional

 

 

 

 

Internal condensate removal (ICR)*

—

—

Optional

 

 

 

 

*Not for use in corrosive environments

 

 

 

**UPC — Universal Power Cord Connection (see pages 42 and 54).

*** Two stage heating if using remote thermostat

265-volt units must be connected in a manner to meet National Electrical Code and all local codes.

8