Instructions

About the controls on the air conditioner.

Features and appearance will vary.

Lights next to the touch pads on the air conditioner control panel indicate the selected settings.

Operating Instructions Safety

NOTE: The display always

Light indicates the unit

shows the room temperature

is in the temperature or

except when setting the Set

delay time Set mode.

temperature or the Delay timer.

 

 

 

 

 

 

 

Light indicates the delay timer is set.

Delay 1–24hr

 

 

 

Delay timer

 

 

Delay timer Increase

Decrease

 

 

 

 

 

Mode select

 

 

Auto Fan on

Fan speed

Fan

Fan

Fan speed Increase

Decrease

 

 

 

Temperature

 

 

Unit power on/off

set Increase

 

 

 

and Decrease

 

 

 

Support Troubleshooting Tips Installation Instructions Care and Cleaning

Air Conditioner Controls

Controls

Power Pad

Turns air conditioner on and off. When turned on, the display will show the room temperature.

Display

Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while setting.

Temp Increase /Decrease Pads

Use to set temperature when in Cool or Energy Saver mode. The Set light will turn on while setting.

Delay Timer Increase(+) /Decrease (–)

Pads

Each touch of the Increase / Decrease pads on the unit or the Increase + / Decrease pads on the remote control will set the delay time when using the Delay 1–24hrtimer ( ). The Set light will turn on while setting.

Fan Speed Pads

Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + / Decrease pads to set the fan speeds to Low, Med or High. Use the Auto pad to turn Auto fan on.

Remote Control

Mode Pad

Use to set the air conditioner to Cool, Energy Saver or Fan Only mode.

Delay Pads

Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.

Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to

24hours.

How to set:

Press the Delay 1–24hrpad on the unit or the

pad on the remote control. Each touch of the Increase / Decreasepads on the unit or the Increase + / Decrease pads on

the remote control will set the timer in

1-hour intervals. The Set light will turn on while setting.

To review the remaining time on the Delay 1–24hrtimer, press the Delay 1–24hrpad on the unit or the pad on the remote control. Use the Increase / Decrease pads on the unit or the Increase + / Decrease pads on the remote control to set a new time if desired.

To cancel the timer, press the Delay 1–24hr pad until the light on the Delay 1–24hr pad goes off.

Consumer

Power Outage Recovery Feature

 

In the case of a power outage or interruption, the

feature was set, it will resume countdown. You may

4

unit will automatically re-start in the settings last

need to set a new time if desired.

 

used after the power is restored. If the Delay 1–24hr

 

Page 4
Image 4
GE AEQ10, AEQ12, AED10*, AED12* About the controls on the air conditioner, Power Outage Recovery Feature

AED12*, AED10*, AEQ12, AEQ10 specifications

The GE AED10*, AED12*, AEQ12, and AEQ10 are sophisticated automated external defibrillators (AEDs) designed to deliver lifesaving treatment during cardiac emergencies. Recognized for their reliability and user-friendly features, these devices are critical tools in promoting cardiac health and enhancing survival rates in cases of sudden cardiac arrest.

One of the standout features of the GE AED series is their intuitive design. The AED10* and AED12* models come equipped with visual and auditory prompts, guiding bystanders through each step of the defibrillation process. This maximizes the likelihood of effective use by untrained individuals, promoting earlier intervention which is vital for survival.

Both the AED10* and AED12* feature a semi-automatic mode, which allows for both automated analysis of the patient’s heart rhythm and manual shock delivery. This flexibility caters to both caregiver preferences and the requirements of the specific emergency situation. The AED12*, in particular, is notable for its advanced capabilities, including real-time ECG monitoring and a built-in memory that stores the event data for later review, enabling healthcare professionals to analyze the situation and fine-tune future emergency responses.

The AEQ12 and AEQ10 also incorporate advanced algorithms that enhance rhythm detection accuracy, ensuring appropriate shocks are delivered only when necessary. These units boast a robust battery life, ensuring they remain functional and ready for use when needed. Their compact and lightweight design makes them portable, enabling quick access in emergencies, whether located in public venues or within private organizations.

In terms of connectivity, both the AEQ12 and AEQ10 support rescue data transmission, allowing incident details to be sent to medical professionals in real time. This feature facilitates a faster response once emergency personnel arrive at the scene, optimizing treatment procedures.

The AED series also emphasizes ruggedness and durability, with many models being resistant to dust and moisture, adhering to high environmental standards. This reliability is crucial, especially in varied locations where the AED may be deployed.

In conclusion, the GE AED10*, AED12*, AEQ12, and AEQ10 are pivotal in emergency care, combining advanced technology, ease of use, and portability. They empower ordinary citizens to act quickly in crises where every second counts, through features that demystify the defibrillation process. As cardiac emergencies can occur anywhere at any time, having these AEDs on hand can significantly improve outcomes during such critical moments.