GE FVR-C9S-7UX instruction manual Function Code Tables

Models: FVR-C9S-7UX

1 44
Download 44 pages 12.86 Kb
Page 23
Image 23

FVR-C9S-7UX

Function Code Tables

Function

Function

Date Code Range

Unit

Min.

Factory

Change

During

Code

Set.

Setting

 

 

 

Operation

 

 

 

 

 

 

F00

Data protection

0: Data change possible

0

No

1: Data change not possible

 

 

 

 

 

 

 

 

 

 

 

 

 

F01

Frequency

0: Keypad panel (UP/DOWN keys)

1

No

Command

1: Analog input (VR, DC0 - 10V or DC4 - 20mA)

 

 

 

 

 

 

 

 

 

 

 

 

F02

Operation

0: Keypad panel operation (RUN/STOP keys)

0

No

Command

1: External signal operation (FWD/REV terminals)

 

 

 

 

 

 

 

 

 

 

 

 

F03

Maximum

50 - 120 Hz

Hz

1

60 Hz

No

Frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

F04

Base Frequency

50 - 120 Hz

Hz

1

60 Hz

No

 

 

 

 

 

 

 

F05

Acceleration TIme

0.0 - 60s (0.0 setting = 0.01s)

s

0.1

6.0s

Yes

 

 

 

 

 

 

 

F06

Deceleration Time

0.0 - 60s (0.0 setting = 0.01s)

s

0.1

6.0s

Yes

 

 

 

 

 

 

 

F07

Torque Boost

0 - 31 (code)

13

Yes

 

 

 

 

 

 

 

 

Electronic Thermal

0: Inactive

 

 

 

 

F08

Overload Relay

1: Active (standard 4-pole motor)

0

No

 

Operation

2: Active (forced-air cooled motor)

 

 

 

 

 

 

 

 

 

 

 

 

Electronic Thermal

 

 

 

 

 

F09

Overload Relay

30 - 105% of rated current of drive

%

1

100%

No

 

Level

 

 

 

 

 

 

 

 

 

 

 

 

 

Restart after

0: Inactive

 

 

 

 

F10

Momentary Power

0

No

1: Active (Restart drive in 0.5s after power failure)

 

Failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F11

Gain for Frequency

0: For 0 - 10 V

0

No

Setting Signal

1: For 0 - 5 V

 

 

 

 

 

 

 

 

 

 

 

 

F12

DC Brake (Level

0 - 100%

1

50%

Yes

Setting)

 

 

 

 

 

 

 

 

 

 

 

 

 

F13

DC Brake (Time)

0.0 (inactive) 0.1 - 30s

s

0.1

0.1s

Yes

 

 

 

 

 

 

 

F14

Starting Frequency

1 - 6 Hz

Hz

1

1 Hz

No

 

 

 

 

 

 

 

C92-01