GE FVR-C9S-7UX instruction manual Multistep Speed Setting 1 Speed, Multistep Speed Setting 2 Speed

Models: FVR-C9S-7UX

1 44
Download 44 pages 12.86 Kb
Page 32
Image 32

 

 

 

FVR-C9S-7UX

 

 

 

Multistep Speed Setting 1 (Speed 1)

F

2

9

F

3

0

Multistep Speed Setting 2 (Speed 2)

F

3

1

Multistep Speed Setting 3 (Speed 3)

Multistep speeds can be set within a range of 0 to 120 Hz only by changing the contact signal from outside. (X1-CM X2-CM). Setting of speed of optional step is possible within a range of 0 to 120 Hz during drive operation

(Note1) X1 or X2 terminal is selected via THR/BX terminal function change (F27, F28) (Note 2) In selecting THR/BX terminal function (F27, F28) individual setting is possible.

Terminal / Function Code

F27 : 1

F27: 0

F27: 1

F27: 0

 

F28: 0

F28: 1

F28: 1

F28: 0

 

 

 

 

 

THR

X1

External Alarm input

X1

External alarm imput

 

 

 

 

 

BX

Motor coast-to-stop

X2

X2

Motor coast-to-stop

command imput

command imput

 

 

 

 

 

 

 

 

C92-09

Speed 0 Frequency setting is made by either the analog signal or the keypad panel.

THR-CM (X1)

BX-CM (X2)

FWD-CM

Speed 1

Speed 2

Speed 3

Speed 0

Time

ON

ON

ON

ON