FVR-C9S-7UX

2) External Signal Operation

Ensure that the connection is as shown in the following diagram in case of operating the drive by means of external frequency setting potentiometer or contact signal.

Power supply

AC220-240V

50/60Hz

1 Phase

Potentiometer for frequency setting

Forward-direction operation command

Reverse-direction operation command

Motor coast-to-stop command

Alarm reset

FAB

 

 

Thermal Relay

L1

8

U

 

8

8

 

 

 

V

M

L2

 

W

 

 

 

CN2

 

13

 

E(G)

 

12

 

 

x

11

 

 

C1

 

 

 

 

 

E(G)

 

 

PE

 

 

 

FWD

 

Fault

 

 

 

 

REV

 

 

30A

 

 

30B

BX (X2)

 

 

 

 

30C

RST

 

 

 

 

 

External alarm input

CM

Analog monitor

THR (X1)

FVR-C9S

FM

10V 1mA

Note 1) Set function F02 to 1.

Note 2) In case of using an external frequency setting potentiometer, disconnect the potenti- ometer connector (CN2) from the keypad panel. Use of an external potentiometer together with the potentiometer on the keypad panel may result in damage to the drive.

*PE terminal blocks for the drive and motor should be provided in the cabinet in which the drive is installed in.