pROVIDE ADEQUATE
GAS SUPPLY
Your range is designed to operate at a pressure
of 4“ of water column on
natiral
gas or, if designed
for
LP
gas
@ropane
or butane), 10” of water
column. Make sure you are supplying your range
with the type of gas for which it is designed. This
range is convertible for use on natural or propane
gas, if you decide to use this range on a different
me
of gas, conversion adjustments must be
made by a service technician or other qualified
person before attempting to operate the range on
that gas.
For proper operation, the pressure of natural gas
supplied to the regulator must be between 4“ and
13” of water column. For
LP
gas, the pressure
supplied must be
be~een
10” and 13” of water
column.
men
checking for proper operation of
the regulator, the inlet pressure must beat least
1“ greater than the operating (manifold) pressure
as given above. The pressure regulator located
at the inlet of the range manifold must remain in
the supply line regardless of whether natural or
LP
gas is being used. A flexible metal appliance
connector used to connect the range to the gas
supply line should have an I.D. of 1/2” and be
5 feet in length for ease of
insta~ation.
In Canada,
flexible connectors must be single wall metal
connectors no longer than 6 feet in length.
CONNECT THE RANGE TO GAS
Shut off the main gas supply valve before
disconnecting the old range and leave it off until
new hook-up has been completed. Don’t forget
to relight the pilot on other gas appliances when
you turn the gas back on.
Because hard piping restricts movement of the
range, the use of an
AG.A.-certKled
flefible
metal appliance connector is recommended
unless local codes require a hard-piped connection.
Never use an old connector when instilling a
new range. If the hard piping method is used,
you must carefully align the pipe; the range
cannot be moved after the connection is made.
To prevent gas leaks, put pipe joint compound
on, or wrap pipe thread tape with Teflon*
around, all male (external) pipe threads.
*Teflon: Registered trademark of DuPont
Gas Pipe and
Eleetric
Outlet locations
for Models Equipped with
sealed
Burners
Gas Pipe and
Eleetrie
Outlet Locations for
Models Equipped with Standard Twin Burners
This area allows
for flush range
installation with
through-the-floor
connection of pipe
stub/shut-off valve.
(continued next page)
31