RS485 INTERFACE (MODBUS RTU)

 

 

 

 

 

COMMUNICATIONS GUIDE

 

 

 

 

 

 

 

 

 

 

 

 

 

Modbus

Hex

Description

Min

Max

Step

Units

Format

Default

Size in

 

 

 

 

 

 

 

 

 

 

 

Words

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40352

015F

IL B Healthy State

0

1

1

---

FC116

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40353

0160

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40357

0164

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40358

0165

IL C Name

0

10

1

---

F22

6

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40368

016F

IL C Function

0

3

1

---

FC140

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40369

0170

IL C Inst Alarm

0

1

1

---

FC126

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40370

0171

IL C Startup Override

0

3600

1

s

F1

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40371

0172

IL C Running Override

0

3601

1

s

F1*

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40372

0173

IL C Healthy State

0

1

1

---

FC116

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40373

0174

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40377

0178

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40378

0179

IL D Name

0

10

1

---

F22

7

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40388

0183

IL D Function

0

3

1

---

FC140

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40389

0184

IL D Inst Alarm

0

1

1

---

FC126

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40390

0185

IL D Startup Override

0

3600

1

s

F1

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40391

0186

IL D Running Override

0

3601

1

s

F1*

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40392

0187

IL D Healthy State

0

1

1

---

FC116

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40393

0188

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40397

018C

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40398

018D

IL E Name

0

10

1

---

F22

8

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40408

0197

IL E Function

0

3

1

---

FC140

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40409

0198

IL E Inst Alarm

0

1

1

---

FC126

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40410

0199

IL E Startup Override

0

3600

1

s

F1

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40411

019A

IL E Running Override

0

3601

1

s

F1*

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40412

019B

IL E Healthy State

0

1

1

---

FC116

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40413

019C

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40417

01A0

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40418

01A1

IL F Name

0

10

1

---

F22

9

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40428

01AB

IL F Function

0

3

1

---

FC140

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40429

01AC

IL F Inst Alarm

0

1

1

---

FC126

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40430

01AD

IL F Startup Override

0

3600

1

s

F1

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40431

01AE

IL F Running Override

0

3601

1

s

F1*

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40432

01AF

IL F Healthy State

0

1

1

---

FC116

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40433

01B0

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40437

01B4

Reserved

---

---

---

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40438

01B5

IL G Name

0

10

1

---

F22

10

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40448

01BF

IL G Function

0

3

1

---

FC140

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40449

01C0

IL G Inst Alarm

0

1

1

---

FC126

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40450

01C1

IL G Startup Override

0

3600

1

s

F1

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40451

01C2

IL G Running Override

0

3601

1

s

F1*

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40452

01C3

IL G Healthy State

0

1

1

---

FC116

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

20

MM300 MOTOR MANAGEMENT SYSTEM – COMMUNICATIONS GUIDE

Page 24
Image 24
GE MM300 manual RS485 Interface Modbus RTU

MM300 specifications

The GE MM300 is a robust and versatile controller designed primarily for industrial automation applications. Built to tackle the demands of modern manufacturing environments, this controller offers a range of features that contribute to its popularity among engineers and operators.

One of the standout features of the GE MM300 is its scalability. The device can be easily configured to meet the needs of both small and large systems. Its modular architecture allows users to add or remove components based on the specific requirements of their applications, facilitating a more tailored approach to automation.

The MM300 supports various communication protocols, including Ethernet/IP, Modbus TCP, and more, ensuring seamless integration with a variety of devices and systems. This feature significantly enhances interoperability, allowing users to connect the controller to existing infrastructure without extensive reconfiguration.

In terms of processing power, the MM300 is equipped with a high-performance processor that can handle complex tasks with ease. With advanced data handling capabilities, it supports real-time data processing, enabling faster decision-making and improving overall operational efficiency. This capability is particularly beneficial for applications requiring precise control and monitoring.

Moreover, the GE MM300 boasts a user-friendly interface, featuring an intuitive programming environment that simplifies the development of control applications. This includes an integrated development environment (IDE) and support for popular programming languages, making it accessible for both seasoned programmers and those new to automation technologies.

The device is designed to operate in challenging industrial conditions, featuring a rugged construction that ensures durability and longevity. Its ability to withstand extreme temperatures, vibrations, and other environmental stressors enhances its reliability in demanding applications, which is crucial for minimizing downtime in production processes.

Security is another critical aspect of the GE MM300. The controller incorporates advanced security features to protect against unauthorized access and cyber threats, helping organizations ensure the integrity of their operations.

In summary, the GE MM300 stands out due to its scalability, versatile communication options, high processing capabilities, user-friendly programming environment, rugged design, and security features. These characteristics make it a reliable choice for industries seeking to enhance their automation processes and improve overall efficiency. Whether for small-scale or large-scale applications, the MM300 provides a comprehensive solution to meet the evolving needs of modern manufacturing.