23

SW2 - Switches 5-8

Switches 5-8 on SW2 are used to modify the communication transfer protocol on Port 2 of the PB3 should the POS device you are using require it. The protocol listed here consists of 3 user definable settings: The Start Bit, The Stop Bit, and Parity. These can be expressed as follows:

Stop Bit: 7 or 8-bit ASCII

Stop Bit: 1 or 2-Stop bits

Parity: Odd, Even, or None

In the following table 8,1,E would translate to 8-start bits, 1-stop bit, and Even parity.

SW2

Protocol

5

6

7

8

7,1,N

U

U

U

U

7,1,O

U

U

U

D

7,1,E

U

U

D

U

8,1,N

U

U

D

D

8,1,O

U

D

U

U

8,1,E

U

D

U

D

7,2,N

U

D

D

U

7,2,O

U

D

D

D

7,2,E

D

U

U

U

8,2,N

D

U

U

D

8,2,O

D

U

D

U

8,2,E

D

U

D

D

Page 23
Image 23
GE PB3-POS-RP user manual Protocol