Installation Instructions
STORAGE TANK AND STARTUP

STORAGE TANK INSTALLATION

1. Remove the protective cap from the top of the
tank.
2. Apply 2–3 wraps
of thread tape,
in a clockwise
direction, to the
tank threads.
3. Install the push-to-connect fittings on the
threaded fitting on the tank as shown.
4. Push the 3/8” red banded tubing from the
Reverse Osmosis System into the fitting on the
storage tank.

SYSTEM STARTUP PROCEDURE

IMPORTANT — If installing the unit in new
construction, ensure that house plumbing is flushed
thoroughly before opening the water supply valve.
1. Check that all tubing connections are secure.
2. Turn on the Feed Water Supply Valve.
3. Check all connection points for leaks.
4. Follow the Sanitization procedures on page 19.
5. After sanitization is complete, reinstall prefilter,
postfilter and Reverse Osmosis cartridges.
6. Membrane contains a food grade preservative.
Allow the system to fill the tank , then drain it
completely four times before using the water
from the system.
7. Recheck all water connection points a few days
later to check for small leaks.
Storage tank
Thread
tape
18