PREPARE ELECTRICAL WIRING

Installation Preparation

PREPARE ELECTRICAL WIRING

FOR PERSONAL SAFETY: Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance.

18"

Receptacle

18" Electrical Requirements Location

Area

Alternate

Receptacle

Location

1-1/2" Dia. Hole (Max.)

AVERTISSEMENT

POUR ASSURER LA SÉCURITÉ PERSONNELLE, il faut enlever le fusible ou couper le courant au disjoncteur avant de commencer l’installation. Avec cet appareil, il ne faut pas utiliser de rallonge ni d’adaptateur de prise.

6" 6"Grounding Instructions–Cable Direct

3"

2"Cabinetfrom

2" 24" from Wall

Ground

Black

White

Electrical Requirements

This appliance must be supplied with 120V, 60 Hz., and connected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.

Wiring must be 2 wire with ground and rated for 75°C (176°F).

If the electrical supply does not meet the above require- ments, call a licensed electrician before proceeding.

Grounding Instructions–Cable Direct

This appliance must be connected to a grounded metal permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and be connected to the equipment-grounding terminal or lead on the appliance.

Grounding Instructions–Power Cord

This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by providing a path of least resistance for electric current. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances.

Electrical Connections to Dishwasher:

The dishwasher junction box is located on the right side at the front of the dishwasher. The electrical cable must extend forward at least 24” to reach the junction box when dishwasher is installed.

The wiring may enter the opening from either side, rear or the floor within the shaded area.

Cut a 1-1/2” max. dia. hole to admit the electrical cable or use the same hole cut for the drain hose. The hole must be free of sharp edges. If the cabinet wall is metal, the hole edge must be covered with a bushing.

For power cord connections, install a 3-prong ground- ing type receptacle in the sink cabinet rear wall, 6" min, or 18" max. from the opening, and 6" to 18" above the floor.

The improper connection of the equip- ment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service represen- tative if you are in doubt that the appli- ance is properly grounded.

AVERTISSEMENT

Le mauvais branchement du fil de mise à la terre de l’équipement peut causer un choc électrique. En cas de doute sur la mise à la terre de l’appareil, consulter un électricien qualifié ou un représentant technique.

7

Page 7