Installation Instructions

LP GAS GRILL CONNECTIONS TO A GRILL OR COOKTOP (cont.)

Single Gas Cooktop or Grill Connection

Outdoor Cooktop: Install the cooktop with a separate tank using the same method. Order WB21X10156 Regulator hose assembly for the

3/8” Flare

Fitting

Built-in models shown.

LP Hose and

Regulator

20-lb. Type 1 LP Tank

20-lb. tank connection.

To connect 20-lb. LP tank:

Attach the regular hose assembly to the brass elbow. Do not use threading compound.

Insert the coupler sleeve on the regulator over the tank inlet; turn clockwise to tighten. Do not overtighten the coupler.

To disconnect from the 20-lb. LP tank:

• Turn tank valve to OFF.

• Grasp the coupler sleeve, turn counterclockwise

and remove.

For models installed on carts, open the tank storage drawer on the right side to make the tank connection.

NATURAL GAS GRILL CONNECTIONS

The gas supply line must be sized to accommodate the outdoor grill and, if present, an outdoor cooktop connected to the same gas supply.

The grill or cooktop and its individual shut-off valve must be disconnected from the gas supply during any pressure testing of the system at test pressures in excess of 1/2 PSIG.

 

1/2" Male to 3/4"

 

Female Elbow

 

Incoming Natural

 

Gas Supply Pipe

 

3/4" NPT to

Regulator

3/4" Flare

Fitting

 

3/4" Min. Dia.

Flexible ConnectorManual Shut-Off

Valve

Built-in models shown.

Make connection for models installed on carts in the same manner. The entry for the gas line is on the back of the cart.

Outdoor Cooktop: Install the cooktop using the same method illustrated above for the outdoor grills.

The installation of the outdoor grills or cooktop must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, latest edition.

Operating pressure is 4" water column. Supply pressure should be 5" to 14" water column. If pressure is more than 14" water column, a step-down regulator is required.

Check with the local gas utility or with local codes for instructions on installing gas supply lines. Be sure to check on type and size of run and how deep to bury the line. If the gas line is too small, the grill will not function properly.

Install a manual gas shut-off valve in an easily accessible location.

Use threading compound on male threads only. Do not use threading compound on the male end of a flare adapter.

Make connections as shown.

Check to be sure the regulator arrow points in the direction of gas flow, towards the grill and away from the gas supply.

17