Questions?

Use this problem solver

Troubleshooting

Advantium Oven

Problem

Possible Causes

What To Do/Explanation

LIGHTS

 

 

 

 

 

Light during a

This is normal.

This is normal. The oven senses the

speedcook cycle

Power level has been

heat level and adjusts automatically.

dims and cycles on

automatically reduced

 

and off, even at full

because the oven is hot.

 

power levels

 

 

 

 

 

Light visible around

This is normal.

When the oven is on, light may

the door and outer

 

be visible around the door and

case while

 

outer case.

speedcooking

 

 

 

 

 

FAN

 

 

 

 

 

Fan continues to run

The oven is cooling.

The fan will automatically shut off

after cooking stops

 

when the internal parts of the oven

 

 

have cooled.

 

 

Oven vent emits warm This is normal.

 

air while oven is on

 

 

 

 

 

Fan comes on

This is normal.

 

automatically when

 

 

using the microwave

 

 

 

 

 

COOKING

 

 

 

 

 

The oven makes

Clicks and fans blowing

These sounds are normal.

unusual sounds

are normal. The relay

 

while cooking

board is turning the

 

 

components on and off.

 

 

 

 

Smoke comes out

Food is high in fat

Smoke is normal when cooking

of the oven when

content. Aerosol spray

high-fat foods.

I open the door

used on the pans.

 

 

 

 

Food is not fully

Programmed times

Increase or decrease time for

cooked or browned

may not match the size

doneness or adjust the upper or

at the end of a

or amount of food you

lower lamps for browning and

cooking program

are cooking.

doneness.

 

 

 

SENSOR ERROR

Food amount or type

Press the CLEAR/OFF pad. Set the

displayed along with

placed in the oven does

oven program to match the food or

an oven signal

not match the program

liquid to be cooked or heated.

 

that was set.

 

 

 

 

Steam was not sensed by Vent plastic wrap, use a looser lid

 

the oven because plastic

or uncover liquids when cooking or

 

wrap was not vented, a lid

heating.

 

too tight was on the dish

 

 

or a liquid was covered.

 

 

 

 

39

Page 39
Image 39
GE ZSC1000, ZSC1001 owner manual Questions? Use this problem solver, Troubleshooting

ZSC1000, ZSC1001 specifications

The GE ZSC1001 and ZSC1000 are advanced digital relays designed for the protection and control of electrical power systems. These devices are part of General Electric's comprehensive portfolio of protection and control solutions. Both relays are engineered to not only ensure the reliability of electrical networks but also to provide robust features that address the evolving needs of modern power systems.

One of the main features of the ZSC1001 and ZSC1000 is their multi-functional protection capabilities. They offer a wide array of protective measures including overcurrent, thermal overload, and phase failure protections. These protective functions are crucial for safeguarding equipment from damage caused by electrical faults. The relays support both directional and non-directional protection schemes, making them versatile for various applications.

Another characteristic of these relays is their advanced communication technologies. The ZSC1001 and ZSC1000 are equipped with multiple communication protocols, such as IEC 61850, which allows for seamless integration into smart grid environments. This interoperability is vital for utility operators looking to implement modern automation strategies and enhance grid reliability.

In terms of visualization and user interface, both models feature an intuitive display and control interface that allows operators to monitor system conditions easily. The graphical user interface simplifies the process of setting parameters, viewing performance data, and troubleshooting issues, making it user-friendly for both seasoned engineers and personnel new to the technology.

The ZSC1001 additionally offers enhanced event recording and reporting capabilities. With a high-resolution event log, operators can analyze fault events and take corrective actions to prevent future occurrences. Coupled with its fast trip times and accuracy, the ZSC1001 is particularly suitable for mission-critical applications where timing and reliability are paramount.

Robustness and ruggedness are also key characteristics of the GE ZSC series. Designed to operate in harsh environments, these relays can withstand extreme temperatures, humidity, and electromagnetic interference. This durability ensures consistent performance even in challenging conditions, making them reliable partners for electrical infrastructure.

In conclusion, the GE ZSC1001 and ZSC1000 digital relays are state-of-the-art devices that combine protective functionality, advanced communication technologies, user-friendly interfaces, and robust designs. Their versatility and comprehensive feature set make them ideal for modern power system applications, supporting utilities and industries in achieving enhanced operational efficiency and reliability.