Installation Instructions
INSTALLATION—VENTED TO THE OUTSIDE

CONNECT ELECTRICAL

Verify that power is turned off at the source.
WARNING:If house wiring is not 2-wire
with a ground wire, a ground must be provided by
the installer. When house wiring is aluminum, be
sure to use U.L. approved anti-oxidant compound
and aluminum-to-copper connectors.
Remove the 6 screws on the junction box cover
and the knockout on the top or left side.
Secure the house wiring to the junction box with
a strain relief.
Connect the white lead to the branch circuit white lead.
Connect the black lead to the branch circuit black lead.
Connect the green/yellow lead to the branch
circuit green lead or bare ground lead.
Secure all the connections with wire nuts on each
electrical connector.
Push the wires into the junction box and replace
the cover. Be sure the wires are not pinched.
Secure the junction box cover with the 6 original
screws.

6INSTALL DUCT COVERS

Remove protective plastic
covering.
Place the decorative duct
covers on top of the hood.
NOTE: The inside duct piece
has vent holes on one end.
The holes are intended for
use when the hood is
installed for recirculating purposes. Slide the inside
end into the outer piece; the vent holes should not
be visible in this installation.
The inside duct piece must slip into the folded ends
of the outer section.
Extend the inner duct upward to the ceiling
bracket.
Press up on the front corners of the filter cover panel
to unlock. Lower the panel to access the filter.
• Locate the screw holes on the inside front edge
of the opening. Install 2 screws to secure the duct
cover to the hood.
7
Mounting
screws
Lower duct
cover seat
Duct cover
support bracket
Lower duct
cover
Upper
duct cover
Duct attachment
tabs
Screw holes
Junction
box cover
12