GE Monogram 3900 Series, 5800 Series manual Power Connection Kits, Zoneline Chassis Nomenclature

Models: 3900 Series 2900 Series 5800 Series

1 60
Download 60 pages 62.88 Kb
Page 3
Image 3
Power Connection Kits

Power Connection Kits

230/208-Volt Line Cord Connection Units

Line Cord

Electric

Electric

Electric

Min. Circuit

Heat

Heater

Heat

Protection

Kit

BTUH

Watts

Amps

(Amps)

 

 

 

 

 

 

RAK3153

8600/7100

2550/2090

11.6/10.6

15

RAK3203

11700/9600

3450/2820

15.5/14.1

20

RAK3303

17100/13900

5000/4090

22.3/20.3

30

Electric Heat Amps include electric heater and fan motor current draw.

Each Line Cord Kit has an integral Leakage Current Detection and Interruption (LCDI) or Arc Fault Current Interrupter (AFCI) device as required by National Electrical Code (NEC) and Underwriters Laboratories (UL) for units manufactured after August 1, 2004.

ge.com

230/208-Volt Sub-Base and Direct Connected Units

 

Direct

Electric

Electric

Electric

Min. Circuit

Sub-Base

Connection

Heat

Heater

Heat

Protection

 

Kit

BTUH

Watts

Amps

(Amps)

 

 

 

 

 

 

RAK204D15P

RAK4157

8600/7100

2550/2090

11.6/10.6

15

RAK204D20P

RAK4207

11700/9600

3450/2820

15.5/14.1

20

RAK204D30P

RAK4307

170100/13900

5000/4090

22.3/20.3

30

Electric Heat Amps include electric heater and fan motor current draw.

Units connected through sub-base do not require a LCDI or AFCI device since they are not considered to be line-cord connected. Each 230/208-volt sub-base kit consists of sub-base with appropriate receptacle for minimum circuit amperage, chaseway to route power connector from sub-base to chassis, wiring to connect sub-base to building wiring and a short line cord with 9-pin connector to connect to chassis and plug into receptacle in sub-base.

Short sub-base line cord may not be used without sub-base. Junction box for 230/208-volt chassis must be purchased separately. RAK4002A for 2900 and 3900 series units RAK4002B for 5800 series units.

265-Volt Sub-Base and Direct Connected Units

Sub-Base

Power

Direct

Electric Heat

Electric Heater

Electric Heat

Min. Circuit Protection

Connection Kit

Connection Kit

BTUH

Watts

Amps

(Amps)

 

RAK204E15

RAK5172

RAK5157

8600

2550

9.6

15

RAK204E20

RAK5202

RAK5207

11700

3450

13.0

20

RAK204E30

RAK5302

RAK5307

17000

5000

18.9

30

Electric Heat Amps include electric heater and fan motor current draw.

265-volt units are to be permanently connected in compliance with National Electrical Code and local codes and have a factory-installed junction box on the chassis. Each 265-volt sub-base kit consists of sub-base with appropriate receptacle for minimum circuit amperage, chaseway to route power connector from sub-base to chassis and wiring to connect sub-base to building wiring.

265-Volt Power Connection Kit must be ordered separately.

Important

Essential Elements Ordering Overview

230/208-volt line cord connected units — order line cord kit 230/208-volt sub-base connected units — order sub-base and junction box 265-volt units — order sub-base and power connection kit

Zoneline® Chassis Nomenclature

The Zoneline chassis is identified by a model number defining the type of unit, cooling capacity, electrical information and optional features included on the unit. When specifying or ordering the Zoneline chassis, the use of this nomenclature will assure receiving the correct unit.

EXAMPLE

A

Z

5

 

8

 

H

1

2

D

A

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zoneline

 

Chassis series

 

 

 

Nominal cooling capacity

 

 

Universal

 

 

 

packaged

 

29=deluxe line cool/

 

07=7,000 BTUH cooling

 

 

power connection

 

 

terminal

 

electric heat

 

 

 

09=9,000 BTUH cooling

 

 

 

 

 

 

 

chassis

 

39=deluxe line heat pump

 

12=12,000 BTUH cooling

 

 

Special Features

 

 

 

 

 

 

58=premium line

 

15=15,000 BTUH cooling

 

 

B=base unit

 

 

 

 

 

 

heat pump

 

 

 

 

 

 

 

 

 

 

C=corrosion treated

 

 

 

 

 

 

 

 

 

 

 

Voltage/Phase/

 

 

D=internal

 

 

 

 

 

 

Unit type

 

 

 

 

Frequency

 

 

 

 

 

condensate

 

 

 

 

 

 

E=cooling with electric

 

 

D=230/208-Volt,

 

 

 

removal (ICR)

 

 

 

 

 

 

resistance heat

 

 

single-phase, 60 Hz

 

 

 

system (heat

 

 

 

 

 

 

H=heat pump with electric

 

 

E=265-Volt, single-phase,

 

 

pump models

 

 

 

 

 

 

resistance heat

 

 

60 Hz

 

 

 

 

 

only) (not for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

coastal areas)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P=Dry Air 25 (2800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Series only)

 

 



Page 3
Image 3
GE Monogram 3900 Series manual Power Connection Kits, Zoneline Chassis Nomenclature, 230/208-VoltLine Cord Connection Units