Introduction

This manual is designed to provide product, performance and application information to our customers and their architects and engineers for use in selection and design of a zonal comfort control system utilizing GE Zoneline® Packaged Terminal Air Conditioners (PTAC) and Packaged Terminal Heat Pumps (PTHP). GE Zoneline PTACs and PTHPs are self-contained units designed for through-the-wall installations in hotels, motels, apartments, hospitals, nursing homes, add-on rooms and many other installations.

Zonelines provide individual room or zone control in both cooling and heating operation. There is a model for practically every application, ranging in cooling capacity from 7,100 to 14,700 BTUH and heating capacity from 6,400 to 13,400 BTUH in heat pump operation. See pages 42 and 54 for resistance heaters available.

Zoneline offers a two-tier lineup: the Deluxe Line and the Premium Line. The Deluxe Line consists of the 2900 Series with electric resistance heat, the 2900 Series Dry Air 25 Models with enhanced dehumidification for hot and humid climates and the 3900 Series heat pump. The 3900 Series heat pump features reverse cycle defrost and simultaneous supplemental resistance heat, when needed, to maintain room comfort.

The Premium Line features the 5800 Series heat pump with reverse cycle defrost and supplemental resistance heat, when needed, to maintain room comfort, plus tactile touch controls with digital display and standard corrosion protection.

Deluxe Line Standard Features:

Digital Controls

—LED Temperature Display —Easy Temperature Selection —Tactile Touch Pad

Universal Heaters

2 Fan Motors

Heat Sentinel

“L” Coil Design Condenser

3-Position Vent Door

Freeze Sentinel

Indoor Coil Frost Control

Central Desk Control Interface

Remote Thermostat Control Interface

Random Restart

Electronic Temperature Limiting

“Smart Fan” Fan Cycle/Continuous Control

Transfer Fan Interface

Reverse Cycle Defrost and Simultaneous Supplemental Resistance Heat on Heat Pumps

Quick Heat Recovery

Deluxe Line Optional Features:

Corrosion Protection

Internal Condensate Removal (on 3900 Series Heat Pump without Corrosion Protection)

NOTE: Dry Air 25 models include all the standard features of the 2900 Series plus standard corrosion protection.

Premium Line Standard Features:

All the Standard Features of the Deluxe Line Plus:

Two fan motor system with Indoor Cross Flow Blower for quieter operation

Unit Diagnostics

Standard Corrosion Protection Treatment

Premium Line Optional Features:

Internal Condensate Removal (Not for use in seacoast or corrosive areas)

Advantages of the GE Zoneline System:

Flexible Application

—May be installed from flush to finished floor to 3" from the ceiling

—7,100 to 14,700 BTUH units in same physical size

—Deluxe 2900 and 3900 Series may be ducted to condition more than one room

—Compatible with Class 2 remote thermostat control

—Compatible with 2 wire CDC or many Energy Management systems

Economical Installation —No ductwork necessary

—No mechanical equipment rooms or pipes required for heating/cooling units

—Replacement units fit existing 42"-wide by 16"-high wall cases

Quiet Operation

—Indoor double cut-off scroll: two fan motor 2900 and 3900 Series units

—Indoor cross-flow blower: 2 fan motor 5800 Series units

Energy-Saving Operation

—Units in unoccupied areas may be turned off

—Designed for efficient cooling operation — EERs from 10.0 to 13.0

—Efficient heat pump units — COPs from 3.2 to 3.6

—Extended heat pump operation without sacrificing room comfort

Ease of Maintenance

—Permanently lubricated fan motors —Upfront lift-out interchangeable filters

—Air Discharge area is easily accessed for cleaning

—Slide-out chassis for easy access for cleaning or if service is required

Reverse Cycle Heat Pump Operation

Both the 3900 and the 5800 Series heat pumps utilize the unique GE PTAC heat pump operation to ensure a comfortable room. The logic used by the units is the same logic used by central system heat pumps to provide greater savings.