Maximum Connected Load
The maximum connected load of a Zoneline® unit occurs when the unit is in resistance heating operation. The maximum amperage shown in the tables below is the combined total of the resistance heater and the indoor fan motor.
230/208-Volt Line Cord Connected Units
|
|
|
| Power Connector Kit |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| RAK3153 |
| RAK3203 |
| RAK3303 | |||
|
| rak4157 |
| RAK4207 |
| RAK4307 | |||
|
| rak204d15p |
| RAK204D20P |
| RAK204D30P | |||
MODEL | 230 V |
| 208 V | 230 V |
| 208 V | 230 V |
| 208 V |
NUMBER |
|
|
| ||||||
|
|
|
|
|
|
|
|
| |
AZ29E07DA* | 11.5 |
| 10.5 | 15.5 |
| 14.1 | N/A |
| N/A |
AZ29E09DA* | 11.5 |
| 10.5 | 15.5 |
| 14.1 | 22.3 |
| 20.3 |
AZ29E12DA* | 11.6 |
| 10.6 | 15.5 |
| 14.1 | 22.3 |
| 20.3 |
AZ29E15DA* | 11.6 |
| 10.6 | 15.6 |
| 14.2 | 22.4 |
| 20.4 |
AZ39H07DA* | 11.5 |
| 10.5 | 15.5 |
| 14.1 | N/A |
| N/A |
AZ39H09DA* | 11.5 |
| 10.5 | 15.5 |
| 14.1 | 22.3 |
| 20.3 |
AZ39H12DA* | 11.6 |
| 10.6 | 15.5 |
| 14.1 | 22.3 |
| 20.3 |
AZ39H15DA* | 11.6 |
| 10.6 | 15.6 |
| 14.2 | 22.4 |
| 20.4 |
AZ58H07DA* | 11.5 |
| 10.5 | 15.5 |
| 14.1 | N/A |
| N/A |
AZ58H09DA* | 11.5 |
| 10.5 | 15.5 |
| 14.1 | 22.3 |
| 20.3 |
AZ58H12DA* | 11.6 |
| 10.6 | 15.5 |
| 14.1 | 22.3 |
| 20.3 |
AZ58H15DA* | 11.6 |
| 10.6 | 15.6 |
| 14.2 | 22.4 |
| 20.4 |
*All versions
Electric Heat Amps include electric heater and fan motor current draw.
Values shown in table above are also the total connected loads for units installed with
RAK204D15P — same as RAK3153
RAK204D20P — same as RAK3203
RAK204D30P — same as RAK3303
265-Volt Units
|
|
| |||
|
|
|
|
|
|
| RAK204E15 |
| RAK204E20 |
| RAK204E30 |
| RAK5172 |
| RAK5202 |
| RAK5302 |
| RAK5157 |
| RAK5207 |
| RAK5307 |
MODEL | 265 V |
| 265 V |
| 265 V |
NUMBER |
|
| |||
|
|
|
|
| |
AZ29E07EA | 10.2 |
| 13.8 |
| N/A |
AZ29E09EA* | 10.2 |
| 13.8 |
| 19.6 |
AZ29E12EA* | 10.3 |
| 13.8 |
| 19.6 |
AZ29E15EA* | 10.3 |
| 13.8 |
| 19.6 |
AZ39H07EA* | 10.2 |
| 13.8 |
| N/A |
AZ39H09EA* | 10.2 |
| 13.8 |
| 19.6 |
AZ39H12EA* | 10.3 |
| 13.8 |
| 19.6 |
AZ39H15EA* | 10.3 |
| 13.8 |
| 19.6 |
AZ58H07EA* | 10.2 |
| 13.8 |
| N/A |
AZ58H09EA* | 10.2 |
| 13.8 |
| 19.6 |
AZ58H12EA* | 10.3 |
| 13.8 |
| 19.6 |
AZ58H15DA* | 10.3 |
| 13.8 |
| 19.6 |
*All versions
Electric Heat Amps include electric heater and fan motor current draw.