Manuals
/
GE Monogram
/
Household Appliance
/
Air Conditioner
GE Monogram
3900 Series manual Typical 2900 Series, 208/230-VoltWiring Diagram, Schematic Diagram
Models:
3900 Series
2900 Series
5800 Series
1
48
60
60
Download
60 pages
62.88 Kb
45
46
47
48
49
50
51
52
<
>
Specification
Install
Typical 2900 Series, 208/230-VoltWiring Diagram
Replacements of Existing Ducted Units
Warranty
Dimension
CDC Terminal Location and Typical Wiring
Compressor Restart Delay
Series Heat Pump with Backup Electric Heat
Easy Clean Air Discharge Area
Page 48
Image 48
Typical 2900 Series,
208/230-Volt
Wiring Diagram
Typical 2900 Series,
208/230-Volt
3900 Series,
208/230-Volt
Schematic Diagram
Wiring Diagrams
48
Page 47
Page 49
Page 48
Image 48
Page 47
Page 49
Contents
GE Zoneline packaged terminal air conditioners
ALL UNITS REQUIRE POWER CONNECTION KIT
3900 Series Heat Pump with Backup Electric Heat
5800 Series Heat Pump with Backup Electric Heat
Quick Reference
Power Connection Kits
Zoneline Chassis Nomenclature
230/208-VoltLine Cord Connection Units
265-Volt Sub-Baseand Direct Connected Units
Deluxe Dry Air 25 Models
The Newest Innovation from GE
Cooling With Resistance Heat
Table of Contents
Features and Benefits
Installation and Dimensions
Product Specifications
Deluxe Line Standard Features
Deluxe Line Optional Features
Premium Line Standard Features
Premium Line Optional Features
Optional Accessories of the Zoneline System
The Zoneline System
Zoneline Features
2900
3900
5800
Features and Benefits
Standard Physical Dimensions
Highly Featured Microprocessor Controls
Quick Heat Recovery - Heat Pump Units
Fan-OnlySetting - HIGH/LOW
Fan-CycleSwitch - “SmartFan”
Compressor Restart Delay
Electronic Temperature Limiting
Easy Clean Air Discharge Area
Up-FrontAir Filters
Concealed Manual Vent Control
Corrosion Protection Optional
Auxiliary Control Switches
Cooling Temperature Limits
Heating Temperature Limits
Right Switches
5800 Series
Auxiliary Control Switches
Cooling Temperature Limits
Heating Temperature Limits
CDC Terminal Location and Typical Wiring
Central Desk Control
Important CDC Comments all series applicable
Maximum Allowable Length
Field Wiring Terminal
Remote Thermostat Control
Resistance Heat Models
RAK806 Universal Control Cover Label
Feature
Heat Pump Models
RAK148D1
RAK148P1
Zoneline Series
Type
Function
Thermostat Model
Heat Pumps and Energy Savings
Balance Point
Heat Pump Operation
Zoneline 3900 and 5800 Series
Zoneline Heat Pump Heat Source Logic
Heat pump condensate
Application Comments
Air Distribution
Dimensions
WALL CASE WITH CHASSIS INSTALLED
RAB71A WALL CASE
RAB77 WALL CASE
Wall Case
Sub-Base
Wall Case Installation Data
Sub-BaseContinued
General
Sub-basesfor the 265 volt units
Architectural Window Louver Installation
Wall Case Installation Data Continued
Window, Curtain and Panel Wall Construction
Masonry Wall Construction
Refer to page 43 for maximum power cord length
Case Angles
FRAMING FOR WALL CASE
FASTENING WALL CASE
Brick Veneer and Frame Construction
WALL SECTION - DETAILED SIDE VIEW
WALL SECTION - DETAILED SIDE VIEW
Cord Set Connected
Sub-BaseConnected
ROOM
WALL CASE INSTALLATION - CORD SET CONNECTED
TOP VIEW
FRONT VIEW
6-1/4± 1/4
See page
1/4 See note
RAB71/77 Wall Case
Temperature-ActivatedDrain Valve
Condensate Disposal Systems
Cooling Condensate
Slinger Ring Systems
WALL CASE WITH RAD10 DRAIN KIT
External Drain. See page 36 for internal drain
WALL CASE WITH RAD10 DRAIN KIT
Internal Drain. See page 35 for external drain
SCREWS
“A” “B”
Ducted Installations
New Ducted Installations
Replacements of Existing Ducted Units
Ducted Application Considerations
DUCTED APPLICATION AZ2800/3800 SERIES
DUCTED DETAILED SIDE VIEWS AZ2800/3800 SERIES
Line Cord Installation
Sub-BaseInstallation
See page 38 for all notes
Exterior Grilles
Exterior Architectural Treatments
and Special Outdoor Grilles
230/208-Volt Line-CordConnected Units
230/208-Volt- Permanently Connected Units
230/208 Volt Sub-Baseand Direct Connected Units
265 Volt Sub-Baseand Direct Connected Units
Replacement of Existing Chassis
Essential Elements Ordering Overview
230/208-Voltand 265-VoltUnits
Line-CordConnected Units
Maximum Connected Load
230/208-VoltLine Cord Connected Units
265-VoltUnits
Power Connector Kit
BTUH at 70º F Indoor Temperature
Cooling Performance Data
Heat Pump Performance Data
Total Capacity - BTUH
Latent System Capacity
MODEL
Outdoor Design Temperature Difference
Normal Yearly Operating Data
Typical 2900 Series, 208/230-VoltWiring Diagram
Schematic Diagram
Wiring Diagrams
Typical 2900 Series, 208/230-Volt
Page
3900 Series, 208/230-VoltSchematic Diagrams
Schematic Diagram of AZ39H AC motor model
Schematic diagram of AZ39H DC motor model
Typical 5800 Series Schematic Diagram
Typical 5800 Series Wiring Diagram
PM ICR
Suggested Bid Form Specifications
Suggested Bid Form Specifications continued
Alternate specification for molded wall case
Specifications for Sub-Baseif required
Receptacles/Sub-Bases
Power connection kits
Zoneline Chassis Nomenclature
Tandem
Preliminary Specifications
Complete Accessory List
Kit Number
Description
General Installation Suggestions
Electrical Wiring Installation
Central Desk Control and Remote Thermostat Wiring
Wall Case/Exterior Grille
Zoneline warranty
What is covered
Ducted Installation Comments
Replacement Installations
Alphabetical Index
Exterior Grille Color Samples
Category
GE Consumer & Industrial
A century of quality and innovation