Installation Preparation
INSTALL CEILING
SUPPORT STRUCTURE
•At the hood location, install 2 x 4 cross framing between ceiling joists as shown.
•The 2 x 4 cross framing can be installed standing or flat. See illustration.
Cross
Framing
16" | ||
Joist | ||
|
Typical Support Frame Mounting
–The framing should be spaced
Cross
Framing
Ceiling
Front of
Hood
Side
ViewSupport
Frame
Note: The cross framing must be spaced
•Arrange cross framing in the ceiling to suit the existing structure. See examples.
–Secure each 2 x 4 block with at least four (4), #10 wood screws, 3″ long (minimum size screws, not
supplied). Use 8 wood screws total for the two supports.
•The cross framing must be accurately aligned to assure correct positioning of the hood.
•The cross framing must be level in all directions. Check with a spirit level and adjust if necessary.
Cross Framing
Ceiling |
Joist
|
| Support | |
Upper Half |
| Frame | |
Front | Opening | ||
Of Support | |||
| |||
Frame | of |
| |
| Hood |
|
Height
Adjustment
Slot
IMPORTANT: The ceiling structure must be capable of supporting the weight of the hood (approximately 100 pounds) and any inadvertent user contact loads. It is recommended that the hood support frame be supported by a minimum of 2 x 4 cross framing.
Finish the Ceiling
Once the ceiling is finished, mark the location of the ceiling joist and cross framing.
•Check to be sure that ceiling is level, use shims if necessary.
1 MOUNT TEMPLATE
•Align the template with the marks on the ceiling and tape in place.
–Be sure the template is oriented correctly, with the front of the hood.
•Use a plumb to be sure the mounting holes will provide parallel alignment with the countertop below.
•Center punch all hole locations.
•Drill pilot holes in the 4 screw locations. Use a 5/32″ bit and drill approximately
deep.
•Cut wire access hole
approximately 1″ dia.
Wire Access Hole
6