Gefen GEF-DVIKVM-848DL user manual RS-232 Features, Functions Syntax

Models: GEF-DVIKVM-848DL

1 49
Download 49 pages 54.24 Kb
Page 20
Image 20

RS-232 SERIAL CONTROL

RS-232 Features

RS-232 remote functions are used to control of this product’s features. Features include input to output routing, EDID storage, EDID management, etc. These functions are available only through the use of the serial port.

Functions Syntax

The syntax for each function is always the same:

Character as the start flag → Function name → Space ( _ ) as function name end flag → Parameter 1 → Space → Parameter n → Carriage Return ( \r ) →

Sample:

#FunctionName_param1_param2_param3_param4...\r

Syntax is NOT case sensitive.

 

EDID Management

 

 

Function

Description

#EDIDDSTOLO

Read downstream EDID and stores into a Local EDID

 

 

#EDIDDSTOBA

Read downstream EDID and stores in EDID Bank

 

 

#EDIDBATOLO

Read downstream EDID and stores in any Local Input

 

 

#EDIDDETOLO

Sets Local EDID to Default EDID

#LOCKEDID

Secures Local EDID

#LOEDIDTOLO

Load EDID file using serial port to one of the local memories

#PRLOEDID

Read Input Local EDID and sends to serial port

#PRDSEDID

Read downstream EDID and sends to serial port

#PRBAEDID

Read EDID from an EDID bank and sends to serial port

 

 

#PREDIDST

Prints EDID details

 

 

17

Page 20
Image 20
Gefen GEF-DVIKVM-848DL user manual RS-232 Features, Functions Syntax