RS-232 SERIAL CONTROL

#LOCKEDID Function

The #LOCKEDID function secures the Local EDID and disables the automatic loading of the downstream EDID after the Matrix is powered on.

Syntax:

#LOCKEDID param1

Parameters:

 

 

param1

Input

[0 - 1]

 

 

 

 

Value

Meaning

 

0

Disable

 

1

Enable

#LOEDIDTOLO Function

The #LOEDIDTOLO function loads an external EDID via RS-232 to any Local EDID input bank.

Syntax:

#LOEDIDTOLO param1 param2 param3

Parameters:

 

 

param1

Input

[1 - 8]

param2

EDID size

[1 - 2]

 

 

 

 

Value

Meaning

 

 

 

 

1

128 byte EDID

 

2

256 byte EDID

param3

eco

[0 - 1]

Notes:

Set param1 to a value of 0 in order to specify all inputs. When using HyperTermi- nal, param3 must be set to 1.