IP CONTROL

The 8x8 DVI KVM Dual Link Matrix supports IP-based control using an integrated Web interface. To access this feature, an IP address, subnet, gateway, and

port number need to be set on the 8x8 DVI KVM Dual Link Matrix (Default IP: 192.168.0.70 Subnet: 255.255.255.0 Gateway: 192.168.0.1 Port: 80). Consult the network administrator to obtain the proper IP address and settings for this product to properly communicate on the network.

The IP control setting can be configured via the RS-232 control interface. Once this has been accomplished, access to the Web Interface is possible.

Simply type the IP address that was assigned to the product in a web browser to access the Matrix Status Page. It should look like the image below.

View Matrix Status

The View Matrix Status will display the current status and can also be used to create routes.

To create a new route, follow the steps below:

1.Select which outputs will display the source by clicking on each check box.

2.Select the radio button of the input that will be routed to each output.

3.Click the SWITCH button to update the new routing configuration.

This page will automatically refresh every minute. However, at anytime the “Refresh” button can be pressed to refresh the status of the Matrix.