Genie GDVRH-604, GDVRH-616, GDVRH-608 manual Alarm

Models: GDVRH-616 GDVRH-608 GDVRH-604

1 93
Download 93 pages 3.9 Kb
Page 63
Image 63



2. Save changes and exit the menu, press the [MENU] button.

Exit the menu without making changes, press the [CANCEL] button.

7.2. ALARM



This DVR supports 4/8/16 Alarm Inputs and 4 x Relay Outputs. One Alarm Input can be configured to one Relay Output. One relay output can be assigned to multiple Alarm Inputs.

1.Use the Left/Right buttons [ ] to select “ALARM” menu tab. The menus are displayed with options in the left-hand column and settings in the right hand column. A cursor

(highlighted menu) can be moved using the directional buttons [ ].

2.INPUT: Change the input type. Use the [-, +] buttons to change the values.

3.OUTPUT: you can configure how the Relay Outputs are controlled: automatic or manual.

1)Use: Change the output type.

2)Inactive: Select turn off method of Relay Out.

a.Event (Automatic): Relay Out is turned OFF when the event expires. This setting is configured globally.

b.Manual: Relay Out is turned OFF from this menu <Control>.

3)Event Edit

- Press [enter] to edit multiple events. The menus are displayed with options in the left- hand column and settings in the right hand column. A cursor (highlighted menu) can

be moved using the directional buttons [ ] on the IR remote or front panel.

65

Page 63
Image 63