2.2.3 RF Output Sample Port (J3) [Type N (F)]
The RF Output Sample port, J3, is located on the bottom of the amplifier as shown in Figure
2.2.4 Monitor & Control Port (J4) [MS3112E18-32S]
The M&C (Monitor and Control) connector is the primary input for controlling the amplifier and monitoring fault conditions. It is a
The Mini Compact Outdoor Amplifier has no on/off switch or circuit breaker in the AC Input path. As soon as AC power is applied to J7, the unit’s power supplies and microcontroller are enabled and the cooling fans should begin to spin. However, the internal amplifier module is disabled until the Mute Line Input (J4, Pin B) is pulled to Ground (J4, Pin V). If it is desired to have the RF enabled every time the AC input is applied, a permanent connection can be made between J4, Pin B and J4, Pin V.
2.2.4.1 Alarms on J4
A variety of alarm signals are present at the M&C connector, J4. Both
2.2.4.1.1 Summary Alarm (J4) Form C Contacts
The Summary Alarm is accessible in both Form C relay and open collector format. The Form C relay is “energized” under normal operating conditions and
2.2.4.1.2 Auxiliary Alarm (J4) Form C Contacts
The Auxiliary Alarm relay is an end user alarm that can be used to signal an alarm condition that is dependent on the state of the Auxiliary Input
The Auxiliary Input is a contact closure to ground. When this input is pulled to ground the Auxiliary Alarm relay is energized (Normal State). When the Auxiliary Input is open circuited the Auxiliary Alarm relay is
2.2.4.1.3 Open Collector Alarm Outputs (J4)
The open collector alarm outputs will require external
•Auxiliary Alarm: follows state of Auxiliary Input as described above
Operations Manual, HPA3, Mini Compact Outdoor SSPA | 208143 REV - | 15 |