Table 8-2: Command Byte Values

varies by the amount of attached data bytes. It may contain 11+N bytes where N is the amount of requested data bytes from a particular table, specified in Data Length field.

The Set Request command allows the sender to actively change parameters for the re- ceiver’s internal configuration. The Set Request frame must contain a number of bytes in the Data Field as specified in Data length field. The frame size must be 11+N bytes, where N is the length of the attached data structure. The receiver will respond with a frame where the command field will be set to a Set Response designator. The frame length is equal to the Request frame. The byte value for each command is given in Table 8-2.

Table 8-2: Command Byte Values

Command Name

Command Byte Value

Set Request

0

 

 

Get Request

1

Set Response

2

 

 

Get Response

3

 

 

8.1.2.4 Data Tag

The SSPA internal structure is organized in several tables, all of which share similar function- ality and internal resources. To access the various tables, the data tag must be specified in the request frame. The data associated with certain tags is read only. Therefore only the “Get” command request would be allowed to access these data tags. The SSPA will return an error on attempts to issue a “Set” request to a read-only table tag. Various tables may contain values formatted either in 1 or 2 bytes format. See Table 8-3.

Table 8-3: Data Tag Byte Values

 

Byte

Minimum

 

Tag Name

valid length

Description

Value

 

of Data Field

 

 

 

 

This tag allows accessing various system settings on remote unit.

System

0

1 byte

Host access status: Full Read/Write access. Settings can be modi-

Tag Settings

fied at any time. Some settings may require hardware reset of the

 

 

 

 

 

remote SSPA unit.

System

1

2 bytes

This tag allows access to the critical unit thresholds. Host access

Threshold Tag

status: Read Only.

 

 

System

 

 

This tag allows access to the unit’s internal conditions flags, such

3

1 byte

as fault status or current system status. Host access status: Read

Conditions Tag

 

 

only. This type of data cannot be set or modified remotely.

 

 

 

ADC Channels

 

 

This tag allows access to the unit’s internal Analog to Digital con-

4

2 bytes

verter. Host access status: Read only. This type of data cannot be

Access Tag

 

 

set or modified remotely.

 

 

 

Packet

6

1 byte

Tag is not used in CO SSPA protocol.

Wrapper

 

 

 

Reserved

2

N/A

This tag is reserved and not used for CO SSPA applications.

Reserved

5

N/A

This tag is reserved for factory usage only.