Parameter 82-Start Options - Continued

Parameter 82-Start Options - Continued

Value Description

Manual Restart. If parameter 21-OPERATING MODE = 2, 3, or 6

4(2-Wire Control) Then Run FWD or REV commands must be removed and then re-applied to start after application of line power.

5

Auto Restart is active after application of line power and Run

Command is given at the Control Terminal Strip.

 

6Synchro Start and Manual Restart

7Synchro Start and Auto Restart

Manual Restart. If parameter 21-OPERATING MODE = 2, 3, or 6 (2-Wire Control) Then Run FWD or REV commands must be removed and then re-applied to start after application of line power.

8Keypad STOP Key is active as a Coast to Stop command. To reset after Keypad Coast to Stop, press Keypad STOP Key again. A STOP Command is given if a command signal is sensed at the Control Terminal Strip and then lost.

Auto Restart is active after application of line power and Run Command is given at the Control Terminal Strip. If parameter

21-OPERATING MODE = 2, 3, 4, 5, 6, or 7 then Keypad STOP Key

9active as a Coast to Stop command. To reset after Keypad Coast to Stop, press Keypad STOP Key again. A STOP Command is given if a command signal is sensed at the Control Terminal Strip and then lost.

Synchro Start and Manual Restart. If parameter 21- OPERATING MODE = 2, 3, 4, 5, 6, or 7 then Keypad STOP Key active as a

10

Coast to Stop command. To reset after Keypad Coast to Stop,

press Keypad STOP Key again. A STOP Command is given if a

 

 

command signal is sensed at the Control Terminal Strip and then

 

lost.

 

 

 

Synchro Start and Auto Restart. If parameter 21- OPERATING

 

MODE = 2, 3, 4, 5, 6, or 7 then Keypad STOP Key active as a

11

Coast to Stop command. To reset after Keypad Coast to Stop,

press Keypad STOP Key again. A STOP Command is given if a

 

 

command signal is sensed at the Control Terminal Strip and then

 

lost.

84-Display Options - Sets the information to be displayed on the keypad LCD display during Run operation. The display will always show set frequency in the Stop Mode and while the output frequency is being set. If set to a value of ª0º the display will indicate Output Frequency (parameter 12-Output

Operation 3-25