Baldor ID101F50-E Operator Keypad, Analog Outputs, Relay Outputs, Fault Conditions, Input Voltage

Models: ID101F50-E

1 74
Download 74 pages 26.37 Kb
Page 11
Image 11
Operator Keypad

Operator Keypad

Display

Custom Backlit LCD

Keypad

8 Key with Tactile Feel

Functions

Output Status Monitoring, Digital Speed Control,

 

Parameter Setting and Display and Fault Log

 

Display

LED Indicators

Red/Green for Status

Analog Outputs

 

Analog Outputs

1 Assignable

Full Scale Range

0 to 10VDC Maximum

Output Conditions

3 conditions plus calibration

 

(see Analog Output Table)

Relay Outputs

 

Relay Outputs

1 Assignable

Rated Voltage

115VAC

Rated Current

1 Ampere Maximum

Conditions

10 conditions (see Relay Output Table)

Fault Conditions

 

Automatic Shutdown

15 conditions (see Fault Code Table)

Watts Loss Data

Catalog No. Horsepower

Input

Voltage

Total Watts Loss

Single Phase

Three Phase

Input

Input

 

 

ID101F50-E

0.5 1PH

115

24

N/A

ID10101-E

1.0 1PH

115

42

N/A

 

 

 

 

 

ID102F50-E

0.5 3PH

230

16

19

ID10201-E

1.0 3PH

230

28

37

 

 

 

 

 

ID10202-E

2.0 3PH

230

52

66

ID102

3.0 3PH

230

66

70

ID102

5.0 3PH

230

70

129

ID10401-E

1.0 3PH

460

N/A

40

ID10402-E

2.0 3PH

460

N/A

67

ID104

3.0 3PH

460

N/A

118

ID104

5.0 3PH

460

N/A

184

 

 

 

 

 

1-6 General Information

Page 11
Image 11
Baldor ID101F50-E manual Operator Keypad, Analog Outputs, Relay Outputs, Fault Conditions, Watts Loss Data, Input Voltage