Arrow is also used to decrement the set speed in the Stop Mode and decrement the actual speed in the Run Mode. The value will decrease at a faster rate after holding the DOWN Arrow key for 5 seconds. Pressing SHIFT while holding the DOWN Arrow will bypass the 5 second delay.
ENTER Used to store a new parameter value when in the Programming Mode. Also used in the Run and Stop Modes to store the current output frequency as the initial output frequency when power is applied to the inverter.
Keypad Status Indicator
The STATUS indicator consists of two LED's, one green and one red. They are visible through a lens in the upper right hand corner of the keypad. The following table defines the STATUS indicator state for the various operating conditions of the inverter.
STATUS INDICATION
OPERATING CONDITION
| Continuous displays | |
Green and Red |
| Power on, Restart (2 Seconds) |
Red |
| Stop, Running in Torque Limit |
Green |
| Run |
|
| Intermittent Displays |
Alternate Green and |
| Running in and out of Torque Limit |
Red Blinking |
|
|
|
|
|
Green Blinking |
| Running in and out of an Overvoltage |
|
| or Undervoltage condition |
Red Blinking |
| Fault Condition, Emergency Stop, |
|
| Auto Restart |
Operation