Baldor ID101F50-E Selection Of Operation Mode And Connection Diagrams, Relay Outputs, Reference

Models: ID101F50-E

1 74
Download 74 pages 26.37 Kb
Page 26
Image 26
Selection Of Operation Mode And Connection Diagrams

Relay Outputs

Programmable relay outputs are available for external monitoring of the drive condition. These outputs are available at terminals NO (Normally Open) and NC (Normally Closed) with a common at terminal RCM (Relay Common). The circuit must be completed by connection at terminals NO or NC and returned to RCM. The output condition for terminals NO and NC is programmed in parameter 75- Relay Output Select. The relay outputs are rated at 115 VAC and 1 Amp maximum.

Selection Of Operation Mode And Connection Diagrams

Several operating modes are available within the Series 10 inverter. These operating modes define the basic operation of the input terminal configurations and motor control setup. The operating modes are selected by the setting of jumper J19, and programming of parameters 21-Operating Mode, 24-Analog Command Select, 41- Accel/Decel/Coast Select, and 77-External Trip Select. These functions are briefly shown below. For a more detailed discussion please refer to Section 3 of this manual.

0-10VDC External

0-5VDC External

Speed

Current

Speed Reference

Speed Reference

Potentiometer

Reference

-￿hield

+

CM

￿IN

REF

-￿hield

+

CM

￿IN

REF

 

￿hield

CM

 

 

 

 

￿IN

CW

 

REF

-￿hield

+

5.2￿DC

CM

￿IN

REF

J19

0￿10￿DC

J19

0￿5￿DC

J19

0￿5￿DC

J19

0￿20 or

4￿20mA

See recommended tightening torques for terminal connectors.

Installation 2-13

Page 26
Image 26
Baldor ID101F50-E manual Selection Of Operation Mode And Connection Diagrams, Relay Outputs, Reference