Parameter 21-Operating Mode

21-Operating Mode - Sets the basic operation of the inverter input terminals and keypad FWD and REV keys. The Series 10 inverter has several modes of operation to fit various application requirements. Please refer to the following table to determine which operating mode is right for your application. The available options include keypad only, control terminal strip only, combination keypad and control terminal strip operation, electronic potentiometer, preset speeds, 2-wire control, and

3-wire control. The factory setting is ª0º, keypad speed control and keypad run FWD only.

Parameter 21-Operating Mode

Value

Speed Control

Start

Control

Type of Control

0

Keypad

Keypad

Keypad FWD Only, 8 Speeds or 4 speeds

 

 

 

with Accel/Decel Select

 

 

 

 

10

Keypad

Keypad

Keypad FWD and REV, 8 Speeds or 4 speeds

 

 

 

with Accel/Decel Select

 

 

 

 

1

Terminals

Keypad

Keypad FWD Only, 8 Speeds or 4 speeds

 

 

 

with Accel/Decel Select

 

 

 

 

11

Terminals

Keypad

Keypad FWD and REV, 8 Speeds or 4 speeds

 

 

 

with Accel/Decel Select

 

 

 

 

 

2

Keypad

Terminals

2-Wire, 8

Speeds or 4 speeds with Accel/De-

 

 

 

cel Select

 

 

 

 

 

3

Terminals

Terminals

2-Wire, 8

Speeds or 4 speeds with Accel/De-

 

 

 

cel Select

 

 

 

 

 

4

Keypad

Terminals

3-Wire, 4

Speeds

5

Terminals

Terminals

3-Wire, 4

Speeds

6

Terminals

Terminals

2-Wire Electronic Pot with 1 Preset Speed or

 

 

 

Accel/Decel Select

 

 

 

 

7

Terminals

Terminals

3-Wire Electronic Pot

3-8 Operation