Notes:
1)The external reference option requires the system operator to provide system reference to the BUC/SSPB. The system will not lock and will have no output without external reference applied.
2)Internal reference option allows for either internal or external reference operation.
The 10 MHz crystal reference used in the internal reference of the converter has the following specifications:
Frequency Stability: | ≤±1 • | |
| ≤±1 • | |
| ≤±5 • | |
Warm up time: | 20 minutes for better than ≤±1 • | |
Phase Noise: | 10 Hz | |
| 100 Hz | |
| 1 KHz | |
| 10 KHz | |
| 100 KHz | |
Frequency Accuracy: | Factory preset to ±1 • |
4.4 FSK Monitor and Control
FSK Monitor and control comes standard with the converter. This allows the Mini Compact Outdoor SSPB to be fully and remotely monitored and controlled through the system’s IFL. An embedded controller enables remote communication and fault detection via the IF input between the SSPA and a Paradise Datacom Evolution Series
The FSK input has a center frequency of 650 KHz with a ±5% tolerance. The FSK deviation is ±60 KHz, with +60 KHz being a “mark” and
Frequency | 650 kHz ± 5% |
FSK Deviation | ± 60 kHz nominal (+60 kHz mark) |
Deviation Tolerance | ± 50 kHz minimum, ± 70 kHz maximum |
Locking Range | ± 32.5 kHz |
Input Level Range | |
Start Tone Time | 10 ms minimum |
See Paradise Datacom document number 201410 for a full description of the VSAT BUC Protocol.
44 | 208143 REV - | Operations Manual, HPA3, Mini Compact Outdoor SSPA |